Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Ultrasound-guided injection for De Quervain's disease: Accuracy and its influenceable anatomical variances in first extensor compartment of fresh cadaver wrists

Authors
Kang, Jong WooPark, Jong WoongLee, Soon HyuckPark, Jong HoonHan, Seung BumPark, Si YoungJeong, Woong Kyo
Issue Date
3월-2017
Publisher
SPRINGER JAPAN KK
Citation
JOURNAL OF ORTHOPAEDIC SCIENCE, v.22, no.2, pp.270 - 274
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF ORTHOPAEDIC SCIENCE
Volume
22
Number
2
Start Page
270
End Page
274
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/84241
DOI
10.1016/j.jos.2016.11.013
ISSN
0949-2658
Abstract
Background: This study was designed to evaluate the accuracy of ultrasound-guided injection targeting EPB tendon sheath and influenceable anatomical variances to the accuracy in the first extensor compartment of fresh cadaver wrists. Methods: Thirty wrists of 15 cadavers were used. The wrists were divided into right-sided wrists (control group) and left-sided wrists (group A) to compare the accuracy of the manual injection technique (control group) and ultrasound-guided injection technique (group A) targeting EPB tendon sheath. To estimate the influence of anatomical variances within first extensor compartment to the accuracy of each injection techniques, control group (manual injection group) was divided into Control group I (right-sided wrists without septum) and II (right-sided wrists with septum) and group A (ultrasound-guided injection group) was also divided into group AI (left-sided wrists without septum) and group AII (left-sided wrists with septum), respectively. After the methylene blue dye injection, the location of methylene blue dye and anatomical variances in the first extensor compartment was identified by dissection. Results: The accuracy was higher in the group A (93.3%) than in control group (40.0%, p < 0.05). The accuracy in control group I (55.6%) was higher than in control group II (16.7%, p < 0.05). The accuracy between group AI (100%) and group AII (85.7%) was not significantly different (p > 0.05). Wrists with more EPB or APL tendon slips showed a tendency not to have septum and all intratendinous injections was occurred in the wrist with 1 EPB tendon slip or 1 or 2 APL tendon slip. Conclusions: Ultrasound-guided injection targeting EPB tendon ensures correct needle placement through the visualization of compartmental anatomy and improves accuracy of injection though the septum in first extensor compartment encourage inaccurate injections. (C) 2016 Published by Elsevier B.V. on behalf of The Japanese Orthopaedic Association.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jong Hoon photo

Park, Jong Hoon
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE