Effect of Implant Diameter on Fatigue Strength
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Song, So-Yeon | - |
dc.contributor.author | Lee, Jeong-Yol | - |
dc.contributor.author | Shin, Sang-Wan | - |
dc.date.accessioned | 2021-09-03T10:19:09Z | - |
dc.date.available | 2021-09-03T10:19:09Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2017-02 | - |
dc.identifier.issn | 1056-6163 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/84745 | - |
dc.description.abstract | Purpose: To investigate the effect of implant diameter on fatigue strength using static and cyclic load test. Materials and Methods: Four different implant systems-SuperLine (Phi 4.0), NRLine (Phi 3.1), SlimLine (Phi 2.8, Phi 2.3), and (Dentium) dwere grouped by implant diameter. A static load test was conducted with 5 specimens for each group using a universal testing machine to measure the ultimate failure load (UFL). With 80% of the UFL in the weakest group, the starting load for a cyclic load test was determined and the test was performed with 8 specimens for each group. All tests were conducted according to ISO14801 (2007) until implant failure occurred. After dynamically loaded, each specimen was sectioned and stereo-microscopically examined. The failure modes of each implant system were classified. Static and cyclic load test data were respectively analyzed after the test of normality, with the level of significance at P = 0.05. Results: In the static load test, the higher maximum load of the standard-diameter implant was significant compared with the recorded narrow or mini-implants (P, 0.05). The yield strengths of the Phi 2.8 and Phi 3.1 implants were significantly greater than that of the Phi 2.3 implant (P < 0.05). In a cyclic load test, the mean number of cycles until implant failure occurred was recorded for each specimen. The value for the Phi 4.0 implant was significantly greater (P < 0.001). Conclusion: Implant diameter has an effect on the ability to withstand both static and cyclic loads within Dentium implant systems, The UFLs and fatigue cycles decreased as the implants diameter became smaller. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | LIPPINCOTT WILLIAMS & WILKINS | - |
dc.subject | FINITE-ELEMENT-ANALYSIS | - |
dc.subject | MINI-IMPLANTS | - |
dc.subject | DENTAL IMPLANTS | - |
dc.subject | TRIAL | - |
dc.title | Effect of Implant Diameter on Fatigue Strength | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Jeong-Yol | - |
dc.contributor.affiliatedAuthor | Shin, Sang-Wan | - |
dc.identifier.doi | 10.1097/ID.0000000000000502 | - |
dc.identifier.scopusid | 2-s2.0-84994655888 | - |
dc.identifier.wosid | 000393668300008 | - |
dc.identifier.bibliographicCitation | IMPLANT DENTISTRY, v.26, no.1, pp.59 - 65 | - |
dc.relation.isPartOf | IMPLANT DENTISTRY | - |
dc.citation.title | IMPLANT DENTISTRY | - |
dc.citation.volume | 26 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 59 | - |
dc.citation.endPage | 65 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | FINITE-ELEMENT-ANALYSIS | - |
dc.subject.keywordPlus | MINI-IMPLANTS | - |
dc.subject.keywordPlus | DENTAL IMPLANTS | - |
dc.subject.keywordPlus | TRIAL | - |
dc.subject.keywordAuthor | narrow-diameter implants | - |
dc.subject.keywordAuthor | mini-implants | - |
dc.subject.keywordAuthor | smaller-diameter implants | - |
dc.subject.keywordAuthor | dynamic fatigue test | - |
dc.subject.keywordAuthor | cyclic load test | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.