Spectacle plane add power of multifocal intraocular lenses according to effective lens position
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Eom, Youngsub | - |
dc.contributor.author | Song, Jong Suk | - |
dc.contributor.author | Kim, Hyo Myung | - |
dc.date.accessioned | 2021-09-03T10:27:44Z | - |
dc.date.available | 2021-09-03T10:27:44Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2017-02 | - |
dc.identifier.issn | 0008-4182 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/84787 | - |
dc.description.abstract | Objective: To evaluate the accuracy of predicting the spectacle plane add power of multifocal intraocular lenses( MIOLs) based on the effective lens position( ELP) using the Haigis formula. Design: Retrospective cross- sectional study. Participants: A total of 26 eyes from 18 consecutive patients who underwent phacoemulsification with Tecnis MIOL( Z* B00) implantation. Methods: The postoperative spectacle plane add power of MIOLs was determined from the monocular defocus curve. The predicted add power error was defined as the difference between the predicted and postoperatively measured spectacle plane add power. The median absolute predicted add power error determined by the preoperatively estimated ELP using the Haigis formula was compared with power error calculated using the value presented by the manufacturer. The correlations among predicted add power error, postoperative spectacle plane add power, and back- calculated ELP were analyzed. Results: The median absolute predicted add power error calculated using the Haigis formula( 0.13D) was significantly smaller than that calculated using the value presented by the manufacturer( 0.26D). The predicted add power error determined by the value presented by the manufacturer was negatively correlated with back- calculated ELP. The postoperative spectacle plane add power was negatively correlated with back- calculated ELP in the ZKB00 IOL( n = 21). Conclusions: The predicted spectacle plane add power of MIOLs using the ELP of the Haigis formula was more accurate than that using the value presented by the manufacturer. The spectacle plane add power of MIOLs decreased as ELP increased. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | CANADIAN OPHTHAL SOC | - |
dc.subject | CATARACT-SURGERY | - |
dc.subject | IMPLANTATION | - |
dc.subject | OUTCOMES | - |
dc.title | Spectacle plane add power of multifocal intraocular lenses according to effective lens position | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Eom, Youngsub | - |
dc.contributor.affiliatedAuthor | Song, Jong Suk | - |
dc.contributor.affiliatedAuthor | Kim, Hyo Myung | - |
dc.identifier.doi | 10.1016/j.jcjo.2016.07.026 | - |
dc.identifier.scopusid | 2-s2.0-85007010246 | - |
dc.identifier.wosid | 000396899600030 | - |
dc.identifier.bibliographicCitation | CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, v.52, no.1, pp.54 - 60 | - |
dc.relation.isPartOf | CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE | - |
dc.citation.title | CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE | - |
dc.citation.volume | 52 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 54 | - |
dc.citation.endPage | 60 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Ophthalmology | - |
dc.relation.journalWebOfScienceCategory | Ophthalmology | - |
dc.subject.keywordPlus | CATARACT-SURGERY | - |
dc.subject.keywordPlus | IMPLANTATION | - |
dc.subject.keywordPlus | OUTCOMES | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.