Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Spectacle plane add power of multifocal intraocular lenses according to effective lens position

Authors
Eom, YoungsubSong, Jong SukKim, Hyo Myung
Issue Date
2월-2017
Publisher
CANADIAN OPHTHAL SOC
Citation
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, v.52, no.1, pp.54 - 60
Indexed
SCIE
SCOPUS
Journal Title
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE
Volume
52
Number
1
Start Page
54
End Page
60
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/84787
DOI
10.1016/j.jcjo.2016.07.026
ISSN
0008-4182
Abstract
Objective: To evaluate the accuracy of predicting the spectacle plane add power of multifocal intraocular lenses( MIOLs) based on the effective lens position( ELP) using the Haigis formula. Design: Retrospective cross- sectional study. Participants: A total of 26 eyes from 18 consecutive patients who underwent phacoemulsification with Tecnis MIOL( Z* B00) implantation. Methods: The postoperative spectacle plane add power of MIOLs was determined from the monocular defocus curve. The predicted add power error was defined as the difference between the predicted and postoperatively measured spectacle plane add power. The median absolute predicted add power error determined by the preoperatively estimated ELP using the Haigis formula was compared with power error calculated using the value presented by the manufacturer. The correlations among predicted add power error, postoperative spectacle plane add power, and back- calculated ELP were analyzed. Results: The median absolute predicted add power error calculated using the Haigis formula( 0.13D) was significantly smaller than that calculated using the value presented by the manufacturer( 0.26D). The predicted add power error determined by the value presented by the manufacturer was negatively correlated with back- calculated ELP. The postoperative spectacle plane add power was negatively correlated with back- calculated ELP in the ZKB00 IOL( n = 21). Conclusions: The predicted spectacle plane add power of MIOLs using the ELP of the Haigis formula was more accurate than that using the value presented by the manufacturer. The spectacle plane add power of MIOLs decreased as ELP increased.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE