Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of treatment outcomes between 10 and 20 EEG electrode location system-guided and neuronavigation-guided repetitive transcranial magnetic stimulation in chronic tinnitus patients and target localization in the Asian brain

Authors
Noh, Tae-SooRah, Yoon-ChanKyong, Jeong SugKim, June SicPark, Moo KyunLee, Jun HoOh, Seung HaChung, Chun KeeSuh, Myung-Whan
Issue Date
2017
Publisher
TAYLOR & FRANCIS LTD
Keywords
Transcranial magnetic stimulation; coil positioning; auditory cortex; prefrontal cortex; tinnitus
Citation
ACTA OTO-LARYNGOLOGICA, v.137, no.9, pp.945 - 951
Indexed
SCIE
SCOPUS
Journal Title
ACTA OTO-LARYNGOLOGICA
Volume
137
Number
9
Start Page
945
End Page
951
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/86330
DOI
10.1080/00016489.2017.1316870
ISSN
0001-6489
Abstract
Objective: rTMS is a non-invasive method that applies a brief magnetic pulse to the cortex and is regarded as a possible therapeutic method for tinnitus control. However, it remains unclear whether the rTMS treatment effect would be the same in tinnitus patients receiving the 10-20 EEG-based target localization as in those receiving imaging-based neuronavigation target localization. Methods: We compared the treatment outcome of the 10-20 EEG-guided rTMS (Group 1) with that of the neuronavigation-guided rTMS (Group 2). Using the individual subject's MRI data and neuronavigation system, the coordinates of the AC relative to the 10-20 EEG system were identified in Asian and compared with those of Caucasian. Results: There was significant improvement in the THI and VAS scores in Group 1 and 2. However, there was no significant difference between the two groups. The location of the AC in Asians was significantly different to that in Caucasians. Conclusion: The 10-20 EEG coordinates of the AC in Asians were significantly different to those in Caucasians. To accurately aim for the AC in Asians, it is recommended that the rTMS be located 1.8 cm superior to the T3 and 0.6 cm posterior to the T3-Cz line. However, because the spatial resolution of the TMS is rather low, this difference probably was not reflected in the treatment outcome.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE