Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Prospective randomized comparison of clinical and angiographic outcomes between everolimus-eluting vs. zotarolimus-eluting stents for treatment of coronary restenosis in drug-eluting stents: intravascular ultrasound volumetric analysis (RESTENT-ISR trial)

Authors
Hong, Soon JunAhn, Chul MinKim, Byeong-KeukKo, Young-GukHur, Seung-HoYu, CheolWoongLee, Seung-JinChoi, Cheol UngKim, Je SangYoon, Jung-HanHong, Young JoonChoi, Jae-WoongChoi, Seung-HyukJang, YangsooLim, Do-Sun
Issue Date
1-12월-2016
Publisher
OXFORD UNIV PRESS
Keywords
Everolimus; Zotarolimus; Neointima; Restenosis
Citation
EUROPEAN HEART JOURNAL, v.37, no.45, pp.3409 - 3418
Indexed
SCIE
SCOPUS
Journal Title
EUROPEAN HEART JOURNAL
Volume
37
Number
45
Start Page
3409
End Page
3418
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/86579
DOI
10.1093/eurheartj/ehw389
ISSN
0195-668X
Abstract
Aims At present no proven standard treatment for drug-eluting stent (DES) restenosis is available, and the efficacy and safety of everolimus-eluting stent (EES) and zotarolimus-eluting stent (ZES) for DES restenosis are limited. The purpose of this prospective, randomized 9-month intracoronary ultrasound (IVUS) and 3-year clinical follow-up study was to compare the effects of EESs and ZESs on neointima volume and major adverse cardiovascular events (MACEs) such as death, myocardial infarction (MI), target lesion revascularization (TLR) and stent thrombosis in DES restenosis patients. Methods and results Patients were eligible for this study if they were between 40 and 75 years old with in-stent restenosis >50% by quantitative coronary angiographic analysis in DES or within 5mm of the stent edges with signs of ischaemia. Eligible patients (n = 304, 146 women and 158 men) were randomly assigned to receive either EES (158 patients) or ZES (146 patients). The primary endpoint of the study was to compare neointima volume between the EES and ZES groups at the 9-month follow-up IVUS. MACEs, including death, non-fatal MI, stent thrombosis and the need for repeated TLR within 3 years, were noted. The 9-month angiographic and IVUS follow-up showed no significant differences in late lumen loss (0.40 +/- 0.56 vs. 0.45 +/- 0.61 mm, P = 0.57, respectively) and neointima volume (0.51 +/- 0.48 vs. 0.56 +/- 0.54mm(3)/1 mm, P = 0.47, respectively) in the EES and the ZES groups. Composite MACEs such as death, MI, stent thrombosis and TLR during 3-year follow-up were comparable between the two groups [15.8% (n = 25) in the EES group and 22.6% (n = 33) in the ZES group, P = 0.276], independent of de novo DES type, sex, age, body mass index, presence of diabetes, hypertension and dyslipidaemia. Conclusions Patients with first- and second-generation DES restenosis, both EES and ZES implantation were effective and safe in reducing neointima volume and late loss with a comparable rate of MACEs independent of cardiovascular risk factors.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Soon Jun photo

Hong, Soon Jun
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE