Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Algorithmic methods of reference-line construction for estimating long-term strength of plastic pipe system

Authors
Moon, JongsubSae, HyunminSong, JaewoongChoi, Sunwoong
Issue Date
12월-2016
Publisher
ELSEVIER SCI LTD
Keywords
Stress-rupture data; Long-term hydrostatic strength; Reference line construction; Algorithmic methods; Miner' s rule
Citation
POLYMER TESTING, v.56, pp.58 - 64
Indexed
SCIE
SCOPUS
Journal Title
POLYMER TESTING
Volume
56
Start Page
58
End Page
64
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/86637
DOI
10.1016/j.polymertesting.2016.09.011
ISSN
0142-9418
Abstract
Two simple and error free methods (direct and interpolation) for obtaining mathematical models for constructing reference lines were developed and successfully applied to the hydrostatic stress-rupture data of polyethylene pipes. Both methods employed an algorithmic process that analyzed the observed stress-rupture data along with its mathematical model of the 50% regression (LTHS) line. For each method, a shift value Delta c was determined and was used to obtain the mathematical model for constructing reference lines that satisfied the requirement of ISO TS 26873. That is, the reference lines so constructed accommodated at least 97.5% of all stress-rupture data points on or above this line, in addition to being parallel to and vertically shifted below the 50% regression lines by an amount Delta c. In the direct method, the reference line was made to pass directly over the data point that is equal to or the first data point greater than the 97.5% data position among all data points. On the other hand, the interpolation method extracted a shift value that corresponded to the 97.5% data position by interpolating between the first data points over and below 97.5%. In this case, the reference lines were made to pass through the interpolated position of 97.5% at every temperature. The advantage of the proposed algorithmic methods is that the determination of mathematical models for reference lines only involves finding the data position(s) with a vertical shift value of Delta c that satisfies the <= 97.5% requirement. With these methods, uncertainties and errors associated with the current trial and error approach for constructing reference lines can be eliminated. In this paper, the details of the algorithmic process for obtaining a proper shift value and using it to develop the mathematical model are described for each method. Also, examples of constructing reference lines using these models are illustrated for polyethylene pipes. (C) 2016 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Electronics and Information Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE