Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of visual peak selection system based on multi-ISs normalization algorithm to apply to methamphetamine impurity profiling

Authors
Lee, Hun JooHan, EunyoungLee, JaesinChung, HeesunMin, Sung-Gi
Issue Date
11월-2016
Publisher
ELSEVIER IRELAND LTD
Keywords
Impurity profiling; Methamphetamine; Normalization algorithm; Methamphetamine impurity profiling
Citation
FORENSIC SCIENCE INTERNATIONAL, v.268, pp.116 - 122
Indexed
SCIE
SCOPUS
Journal Title
FORENSIC SCIENCE INTERNATIONAL
Volume
268
Start Page
116
End Page
122
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/87117
DOI
10.1016/j.forsciint.2016.09.019
ISSN
0379-0738
Abstract
The aim of this study is to improve resolution of impurity peaks using a newly devised normalization algorithm for multi-internal standards (ISs) and to describe a visual peak selection system (VPSS) for efficient support of impurity profiling. Drug trafficking routes, location of manufacture, or synthetic route can be identified from impurities in seized drugs. In the analysis of impurities, different chromatogram profiles are obtained from gas chromatography and used to examine similarities between drug samples. The data processing method using relative retention time (RRT) calculated by a single internal standard is not preferred when many internal standards are used and many chromatographic peaks present because of the risk of overlapping between peaks and difficulty in classifying impurities. In this study, impurities in methamphetamine (MA) were extracted by liquid-liquid extraction (LLE) method using ethylacetate containing 4 internal standards and analyzed by gas chromatography-flame ionization detection (GC-FID). The newly developed VPSS consists of an input module, a conversion module, and a detection module. The input module imports chromatograms collected from GC and performs preprocessing, which is converted with a normalization algorithm in the conversion module, and finally the detection module detects the impurities in MA samples using a visualized zoning user interface. The normalization algorithm in the conversion module was used to convert the raw data from GC-FID. The VPSS with the built-in normalization algorithm can effectively detect different impurities in samples even in complex matrices and has high resolution keeping the time sequence of chromatographic peaks the same as that of the RRT method. The system can widen a full range of chromatograms so that the peaks of impurities were better aligned for easy separation and classification. The resolution, accuracy, and speed of impurity profiling showed remarkable improvement. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Min, Sung Gi photo

Min, Sung Gi
컴퓨터학과
Read more

Altmetrics

Total Views & Downloads

BROWSE