Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position

Authors
Eom, YoungsubRyu, DongokKim, Dae WookYang, Seul KiSong, Jong SukKim, Sug-WhanKim, Hyo Myung
Issue Date
10월-2016
Publisher
SPRINGER
Keywords
Toric intraocular lens; Posterior corneal astigmatism; Incision-induced astigmatism; Effective lens position
Citation
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, v.254, no.10, pp.1977 - 1986
Indexed
SCIE
SCOPUS
Journal Title
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
Volume
254
Number
10
Start Page
1977
End Page
1986
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/87270
DOI
10.1007/s00417-016-3446-3
ISSN
0721-832X
Abstract
Background To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Methods Two thousand samples of corneal parameters with keratometric astigmatism >= 1.0 D were obtained using boot-strap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. Results The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. Conclusions The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE