Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

In vitro assessment of the marginal and internal fits of interim implant restorations fabricated with different methods

Authors
Park, Jin-YoungJeong, Il-DoLee, Jae-JunBae, So-YeonKim, Ji-HwanKim, Woong-Chul
Issue Date
10월-2016
Publisher
MOSBY-ELSEVIER
Citation
JOURNAL OF PROSTHETIC DENTISTRY, v.116, no.4, pp.536 - 542
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PROSTHETIC DENTISTRY
Volume
116
Number
4
Start Page
536
End Page
542
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/87309
DOI
10.1016/j.prosdent.2016.03.012
ISSN
0022-3913
Abstract
Statement of problem. The fit of an interim implant restoration (IIR) is important for the effective treatment of patients with partial edentulism. However, no clinical trials have evaluated the marginal and internal fittings achieved with various fabrication methods. Purpose. The purpose of this in vitro study was to evaluate and compare the marginal and internal discrepancies in IIRs produced with 3 different methods. Material and methods. Partially edentulous maxillary and mandibular casts from a transfer abutment were used. Prostheses were prepared by applying wax to the implant abutment. Shapes were copied using putty. IIRs were fabricated from poly(methyl methacrylate) for a conventional system with thermoplastic resin (CTR, n=40), a 4-axial milling machine with a crown-designed standard template library for a subtractive manufacturing system with Pekkton milling (SPM, n=40), and a 3-dimensional printer for an additive manufacturing system with digital light processing (ADL, n=40). The marginal and internal discrepancies were evaluated in each group using the silicone replica technique. The space between the abutment and the intaglio surface of the prosthesis was evaluated with a digital microscope (x160 magnification). Results were analyzed with nonparametric 2-way analysis of variance using rank-transformed values and Tukey post hoc test (alpha=.05). Results. The fabricated IIRs were significantly different at all points (P<.001). Moreover, ADL was superior to CTR and SPM. IIRs were significantly different only at the intermarginal discrepancy (the vertical discrepancy between the crown and the point where the margin becomes round and changes to the axial wall), the axiogingival discrepancy (the vertical discrepancy between the internal surface and the axial wall adjacent to the gingival wall of the abutment), and the occlusal discrepancy (the vertical discrepancy between the occlusal wall of the abutment and the internal surface; this discrepancy comprises the internal discrepancy; P<.001). No significant differences were found among the IIRs at the marginal discrepancy (the vertical discrepancy between the abutment margin and the crown; P>.111) and the axio-occlusal discrepancy (the vertical discrepancy between the axial wall adjacent to the occlusal wall of the abutment and the internal surface; this discrepancy comprises the internal discrepancy; P>.257). Conclusions. ADL was superior to the other 2 fabrication methods. However, all 3 methods were suitable because they produced a marginal fit which was within the clinically acceptable range.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE