Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis

Authors
Moon, Young-WanKim, Hyun-JungAhn, Hyeong-SikPark, Chan-DeokLee, Dae-Hee
Issue Date
9월-2016
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
gap balancing; measured resection; total knee arthroplasty
Citation
MEDICINE, v.95, no.39
Indexed
SCIE
SCOPUS
Journal Title
MEDICINE
Volume
95
Number
39
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/87693
DOI
10.1097/MD.0000000000005006
ISSN
0025-7974
Abstract
Background:This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty.Methods:Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies.Results:The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (-0.09mm, 95% confidence interval [CI]: -0.40 to +0.21mm; P = 0.55), except that the medial/LEG difference was 0.58mm greater for measured resection than gap balancing (95% CI: -1.01 to -0.15mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77 degrees, 95% CI: 0.18 degrees to 1.35 degrees; P = 0.01) and joint line change (1.17mm, 95% CI: 0.82 to 1.52mm; P<0.001) were significantly greater for the gap balancing than the measured resection technique.Conclusion:The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal (around 1mm or 1 degrees) and therefore may have little effect on the biomechanics of the knee joint. This suggests that the gap balancing and measured resection techniques are not mutually exclusive.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE