Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Radiation tests of real-sized prototype RPCs for the Phase-2 Upgrade of the CMS Muon System

Authors
Lee, K. S.Cho, S. W.Choi, S. Y.Hong, B.Go, Y.Kang, M. H.Lim, J. H.Park, S. K.Cimmino, A.Crucy, S.Fagot, A.Gul, M.Rios, A. A. O.Tytgat, M.Zaganidis, N.Aly, S.Assran, Y.Radi, A.Sayed, A.Singh, G.Abbrescia, M.Iaselli, G.Maggi, M.Pugliese, G.Verwilligen, P.van Doninck, W.Colafranceschi, S.Sharma, A.Benussi, L.Bianco, S.Piccolo, D.Primavera, F.Bhatnagar, V.Kumarl, R.Metha, A.Singh, J.Ahmad, A.Ahmad, M.Ahmed, W.Asghar, M. I.Awan, I. M.Hassan, Q.Hoorani, H.Khan, W. A.Khurshid, T.Muhammad, S.Shah, M. A.Shahzad, H.Kim, M. S.Goutzvitz, M.Grenier, G.Lagarde, F.Laktineh, I. B.Carpinteyro Bernardino, S.Uribe Estrada, C.Pedraza, I.Severiano, C. B.Carrillo Moreno, S.Vazquez Valencia, F.Pant, L. M.Buontempo, S.Cavallo, N.Esposito, M.Fabozzi, F.Lanza, G.Lista, L.Meola, S.Merola, M.Orso, I.Paolucci, P.Thyssen, F.Braghieri, A.Magnani, A.Montagna, P.Riccardi, C.Salvini, P.Vai, I.Vitulo, P.Ban, Y.Qian, S. J.Choi, M.Choi, Y.Goh, J.Kim, D.Aleksandrov, A.Hadjiiska, R.Iaydjiev, P.Rodozov, M.Stoykova, S.Sultanov, G.Vutova, M.Dimitrov, A.Litov, L.Pavlov, B.Petkov, P.Lomidze, D.Avila, C.Cabrera, A.Sanabria, J. C.Crotty, I.Vaitkus, J.
Issue Date
8월-2016
Publisher
IOP PUBLISHING LTD
Keywords
Resistive-plate chambers; Gaseous detectors; Trigger detectors
Citation
JOURNAL OF INSTRUMENTATION, v.11
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF INSTRUMENTATION
Volume
11
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/87870
DOI
10.1088/1748-0221/11/08/C08008
ISSN
1748-0221
Abstract
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for the Phase-2 upgrade of the CMS muon system at high eta. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs with cosmic rays and with 100-GeV muons provided by the SPS H4 beam line at CERN. To examine the rate capability of the prototype RPCs both at Korea University and at the CERN GIF++ facility, the chambers were irradiated with Cs-137 sources providing maximum gamma rates of about 1.5 kHz cm(-2). For the 1.6-mm-thick double-gap RPCs, we found the relatively high threshold on the produced detector charge was conducive to effectively suppressing the rapid increase of strip cluster sizes of muon hits with high voltage, especially when measuring the narrow-pitch strips. The gamma-induced currents drawn in the four-gap RPC were about one-fourth of those drawn in the double-gap RPC. The rate capabilities of both RPC types, proven through the present testing using gamma-ray sources, far exceeded the maximum rate expected in the new high-eta endcap RPCs planned for future phase-II runs of the Large Hadron Collider (LHC).
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, Su yong photo

CHOI, Su yong
이과대학 (물리학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE