Impact of non-compliant balloons on long-term clinical outcomes in coronary bifurcation lesions: results from the COBIS (COronary Bifurcation Stent) II registry
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Taek Kyu | - |
dc.contributor.author | Lee, Jae-Hwan | - |
dc.contributor.author | Song, Young Bin | - |
dc.contributor.author | Jeong, Jin-Ok | - |
dc.contributor.author | Hahn, Joo-Yong | - |
dc.contributor.author | Yang, Jeong Hoon | - |
dc.contributor.author | Choi, Seung-Hyuk | - |
dc.contributor.author | Choi, Jin-Ho | - |
dc.contributor.author | Lee, Sang Hoon | - |
dc.contributor.author | Jeong, Myung-Ho | - |
dc.contributor.author | Kim, Hyo-Soo | - |
dc.contributor.author | Oh, Ju Hyeon | - |
dc.contributor.author | Yu, Cheol Woong | - |
dc.contributor.author | Rha, Seung Woon | - |
dc.contributor.author | Jang, Yangsoo | - |
dc.contributor.author | Yoon, Jung Han | - |
dc.contributor.author | Tahk, Seung-Jea | - |
dc.contributor.author | Seung, Ki Bae | - |
dc.contributor.author | Park, Jong-Seon | - |
dc.contributor.author | Gwon, Hyeon-Cheol | - |
dc.date.accessioned | 2021-09-03T22:11:55Z | - |
dc.date.available | 2021-09-03T22:11:55Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2016-07 | - |
dc.identifier.issn | 1774-024X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/88115 | - |
dc.description.abstract | Aims: Non-compliant balloons provide uniform radial force along the vessel wall at any inflation pressure. As a result, the use of non-compliant balloons may reduce side branch complications and optimise stent deployment. We sought to investigate the impact of non-compliant balloons on the long-term clinical outcomes of patients undergoing a coronary bifurcation intervention. Methods and results: A total of 2,897 patients treated with drug-eluting stents for bifurcation lesions were enrolled. Non-compliant balloons were used in 752 patients (26%). During a median three-year follow-up, major adverse cardiac events (MACE: cardiac death, myocardial infarction, or target lesion revascularisation) occurred less frequently in the non-compliant balloon group than in the compliant balloon group (8.2% versus 10.9%; p=0.03). After propensity score matching (710 pairs), the use of non-compliant balloons resulted in a lower rate of side branch dissection (0.1% versus 1.1%; p=0.046) and a higher rate of procedural success (79.0% versus 73.9%; p=0.01). The use of non-compliant balloons was associated with a lower risk of MACE (HR 0.64, 95% CI: 0.46-0.91; p=0.01) and cardiac death (HR 0.14, 95% CI: 0.03-0.64; p=0.01). Conclusions: The use of non-compliant balloons was associated with favourable procedural and long-term clinical outcomes in patients receiving coronary bifurcation intervention. ClinicalTrials.gov number: NCT01642992 | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | EUROPA EDITION | - |
dc.subject | DRUG-ELUTING STENTS | - |
dc.subject | ARTERY BIFURCATION | - |
dc.subject | INTERVENTION | - |
dc.subject | DEPLOYMENT | - |
dc.subject | TRIALS | - |
dc.subject | CRUSH | - |
dc.title | Impact of non-compliant balloons on long-term clinical outcomes in coronary bifurcation lesions: results from the COBIS (COronary Bifurcation Stent) II registry | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yu, Cheol Woong | - |
dc.contributor.affiliatedAuthor | Rha, Seung Woon | - |
dc.identifier.doi | 10.4244/EIJV12I4A79 | - |
dc.identifier.scopusid | 2-s2.0-84983070582 | - |
dc.identifier.wosid | 000381777500008 | - |
dc.identifier.bibliographicCitation | EUROINTERVENTION, v.12, no.4, pp.456 - 464 | - |
dc.relation.isPartOf | EUROINTERVENTION | - |
dc.citation.title | EUROINTERVENTION | - |
dc.citation.volume | 12 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 456 | - |
dc.citation.endPage | 464 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Cardiovascular System & Cardiology | - |
dc.relation.journalWebOfScienceCategory | Cardiac & Cardiovascular Systems | - |
dc.subject.keywordPlus | DRUG-ELUTING STENTS | - |
dc.subject.keywordPlus | ARTERY BIFURCATION | - |
dc.subject.keywordPlus | INTERVENTION | - |
dc.subject.keywordPlus | DEPLOYMENT | - |
dc.subject.keywordPlus | TRIALS | - |
dc.subject.keywordPlus | CRUSH | - |
dc.subject.keywordAuthor | Angioplasty | - |
dc.subject.keywordAuthor | Coronary bifurcation | - |
dc.subject.keywordAuthor | Non-compliant balloon | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.