Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Impact of non-compliant balloons on long-term clinical outcomes in coronary bifurcation lesions: results from the COBIS (COronary Bifurcation Stent) II registry

Authors
Park, Taek KyuLee, Jae-HwanSong, Young BinJeong, Jin-OkHahn, Joo-YongYang, Jeong HoonChoi, Seung-HyukChoi, Jin-HoLee, Sang HoonJeong, Myung-HoKim, Hyo-SooOh, Ju HyeonYu, Cheol WoongRha, Seung WoonJang, YangsooYoon, Jung HanTahk, Seung-JeaSeung, Ki BaePark, Jong-SeonGwon, Hyeon-Cheol
Issue Date
7월-2016
Publisher
EUROPA EDITION
Keywords
Angioplasty; Coronary bifurcation; Non-compliant balloon
Citation
EUROINTERVENTION, v.12, no.4, pp.456 - 464
Indexed
SCIE
SCOPUS
Journal Title
EUROINTERVENTION
Volume
12
Number
4
Start Page
456
End Page
464
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/88115
DOI
10.4244/EIJV12I4A79
ISSN
1774-024X
Abstract
Aims: Non-compliant balloons provide uniform radial force along the vessel wall at any inflation pressure. As a result, the use of non-compliant balloons may reduce side branch complications and optimise stent deployment. We sought to investigate the impact of non-compliant balloons on the long-term clinical outcomes of patients undergoing a coronary bifurcation intervention. Methods and results: A total of 2,897 patients treated with drug-eluting stents for bifurcation lesions were enrolled. Non-compliant balloons were used in 752 patients (26%). During a median three-year follow-up, major adverse cardiac events (MACE: cardiac death, myocardial infarction, or target lesion revascularisation) occurred less frequently in the non-compliant balloon group than in the compliant balloon group (8.2% versus 10.9%; p=0.03). After propensity score matching (710 pairs), the use of non-compliant balloons resulted in a lower rate of side branch dissection (0.1% versus 1.1%; p=0.046) and a higher rate of procedural success (79.0% versus 73.9%; p=0.01). The use of non-compliant balloons was associated with a lower risk of MACE (HR 0.64, 95% CI: 0.46-0.91; p=0.01) and cardiac death (HR 0.14, 95% CI: 0.03-0.64; p=0.01). Conclusions: The use of non-compliant balloons was associated with favourable procedural and long-term clinical outcomes in patients receiving coronary bifurcation intervention. ClinicalTrials.gov number: NCT01642992
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Rha, Seung Woon photo

Rha, Seung Woon
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE