Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Primary stability of inferior tilt fixation of the glenoid component in reverse total shoulder arthroplasty: A finite element study

Authors
Chae, Soo-WonLee, HaeaKim, Soo MinLee, JuneyoungHan, Seung-HoKim, Soung-Yon
Issue Date
Jun-2016
Publisher
WILEY
Keywords
reverse total shoulder arthroplasty; glenoid component; inferior tilt; finite element analysis; primary stability
Citation
JOURNAL OF ORTHOPAEDIC RESEARCH, v.34, no.6, pp.1061 - 1068
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF ORTHOPAEDIC RESEARCH
Volume
34
Number
6
Start Page
1061
End Page
1068
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/88457
DOI
10.1002/jor.23115
ISSN
0736-0266
Abstract
Glenoid component fixation with inferior tilt has been suggested as one of the surgical methods to decrease scapular notching and improve stability, but its clinically beneficial effect remains a concern. We evaluated the influence of inferior tilt fixation of the glenoid component on primary stability in reverse total shoulder arthroplasty by finite element analysis. Finite element models were constructed from cadaveric scapulae of females over the age of 60 years and glenoid components from reverse total shoulder arthroplasty. The relative micromotion at the bone-glenoid component interface, distribution of bone stress under the glenoid component and around the screws, contact area between the bone and screws, and cut surface area of the cancellous bone exposed after glenoid reaming were analyzed and compared between a neutral and 10 degrees inferior tilt fixation of the glenoid component. The 10 degrees inferior tilt fixation demonstrated greater relative micromotion and higher bone stress than the neutral tilt fixation. Eccentric reaming, which is done to produce the inferior tilt fixation of the glenoid component, increased glenoid cancellous bone exposure and decreased bone-screws contact area. Inferior tilt fixation of the glenoid component may adversely affect primary stability and longevity after reverse total shoulder arthroplasty. (c) 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1061-1068, 2016.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE