Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Automated Micro-Object Detection for Mobile Diagnostics Using Lens-Free Imaging Technology

Authors
Roy, MohendraSeo, DongminOh, SangwooChae, YeonghunNam, Myung-HyunSeo, Sungkyu
Issue Date
6월-2016
Publisher
MDPI
Keywords
lens-free; algorithm; telemedicine; cytometer; RBC
Citation
DIAGNOSTICS, v.6, no.2
Indexed
SCOPUS
Journal Title
DIAGNOSTICS
Volume
6
Number
2
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/88480
DOI
10.3390/diagnostics6020017
ISSN
2075-4418
Abstract
Lens-free imaging technology has been extensively used recently for microparticle and biological cell analysis because of its high throughput, low cost, and simple and compact arrangement. However, this technology still lacks a dedicated and automated detection system. In this paper, we describe a custom-developed automated micro-object detection method for a lens-free imaging system. In our previous work (Roy et al.), we developed a lens-free imaging system using low-cost components. This system was used to generate and capture the diffraction patterns of micro-objects and a global threshold was used to locate the diffraction patterns. In this work we used the same setup to develop an improved automated detection and analysis algorithm based on adaptive threshold and clustering of signals. For this purpose images from the lens-free system were then used to understand the features and characteristics of the diffraction patterns of several types of samples. On the basis of this information, we custom-developed an automated algorithm for the lens-free imaging system. Next, all the lens-free images were processed using this custom-developed automated algorithm. The performance of this approach was evaluated by comparing the counting results with standard optical microscope results. We evaluated the counting results for polystyrene microbeads, red blood cells, HepG2, HeLa, and MCF7 cells lines. The comparison shows good agreement between the systems, with a correlation coefficient of 0.91 and linearity slope of 0.877. We also evaluated the automated size profiles of the microparticle samples. This Wi-Fi-enabled lens-free imaging system, along with the dedicated software, possesses great potential for telemedicine applications in resource-limited settings.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Electronics and Information Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Nam, Myung Hyun photo

Nam, Myung Hyun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE