Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial

Authors
Park, Eun-AhLee, WhalKang, Doo KyoungKim, Sung JinKim, Young-JuKim, YookyungSung, Yon MiSong, Soon-YoungOh, Yu-WhanYong, Hwan SeokLee, HeonJeon, Eui-YongJin, Gong-YongChoi, Byoung WookChoi, Sang-Il
Issue Date
May-2016
Publisher
KOREAN RADIOLOGICAL SOC
Keywords
Coronary arteries; Contrast media; Contrast materials; Drug safety; Image quality enhancement
Citation
KOREAN JOURNAL OF RADIOLOGY, v.17, no.3, pp.330 - 338
Indexed
SCIE
SCOPUS
KCI
Journal Title
KOREAN JOURNAL OF RADIOLOGY
Volume
17
Number
3
Start Page
330
End Page
338
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/88719
DOI
10.3348/kjr.2016.17.3.330
ISSN
1229-6929
Abstract
Objective: This multi-center, randomized, double-blind, phase 3 trial was conducted to compare the safety and efficacy of contrast agents iohexol-380 and iohexol-350 for coronary CT angiography in healthy subjects. Materials and Methods: Volunteers were randomized to receive 420 mgI/kg of either iohexol-350 or iohexol-380 using a flow rate of 4 mL/sec. All adverse events were recorded. Two blinded readers independently reviewed the CT images and conflicting results were resolved by a third reader. Luminal attenuations (ascending aorta, Left main coronary artery, and Left ventricle) in Hounsfield units (HUs) and image quality on a 4-point scale were calculated. Results: A total of 225 subjects were given contrast media (115 with iohexol-380 and 110 with iohexoL-350). There was no difference in number of adverse drug reactions between groups: 75 events in 56 (48.7%) of 115 subjects in the iohexol-380 group vs. 74 events in 51 (46.4%) of 110 subjects in the iohexol-350 group (p = 0.690). No severe adverse drug reactions were recorded. Neither group showed an increase in serum creatinine. Significant differences in mean density between the groups was found in the ascending aorta: 375.8 71.4 HU with iohexol-380 vs. 356.3 61.5 HU with iohexoL-350 (p = 0.030). No significant differences in image quality scores between both groups were observed for all three anatomic evaluations (all, p > 0.05). Conclusion: Iohexol-380 provides improved enhancement of the ascending aorta and similar attenuation of the coronary arteries without any increase in adverse drug reactions, as compared with iohexol-350 using an identical amount of total iodine.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Yu Whan photo

Oh, Yu Whan
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE