Indoor Air Quality Performance of Ventilation Systems in Classrooms

Authors
Moon, Hyeun JunSohn, Jong-RyeulHwang, Taeyon
Issue Date
May-2016
Publisher
ARCHITECTURAL INST JAPAN
Keywords
indoor air quality; performance of ventilation system; ventilation rate requirement; IAQ for classroom
Citation
JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, v.15, no.2, pp.343 - 348
Indexed
SCIE
AHCI
SCOPUS
Journal Title
JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING
Volume
15
Number
2
Start Page
343
End Page
348
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/88740
DOI
10.3130/jaabe.15.343
ISSN
1346-7581
Abstract
This study aims to evaluate the field performance and the efficiency of ventilation systems in school buildings. Three classrooms installed with ventilation systems in a high school in Seoul were selected as a test bed for this study. The ventilation systems consisted of two types of multi air-conditioning ventilation system and a window type air-conditioning ventilation system. The ventilation performance was measured by the blower door and tracer gas methods as follows: (1) Evaluation of air tightness and air infiltration in the classrooms; (2) Indoor ventilation performance based on the operating condition of ventilation systems; (3) Ventilation performance based on the operating conditions of ventilation systems and air-conditioners; and (4) Local ventilation efficiency and performance based on the operating status of the ventilation systems and air-conditioners. As a result, the ventilation efficiency was measured at 34.8%-97.8% for the duct type of ventilation and 82.6% for the window type ventilation. In this study, classroom characteristics such as high air infiltration low air tightness lowered the ventilation effectiveness. The ventilation efficiency varied based on the location of air inlet and outlet ducts and the existence of furniture. However, local ventilation efficiency was not significantly affected according to the results of this study. The results showed that a ventilation rate of 1000 cubic meters per hour (CMH) or more would be required to maintain 1000 ppm of CO2 concentrations as per IAQ criteria for Korean classrooms.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE