An inner-crystal neutron-scatter camera: Monte carlo simulation

Authors
Jo, AjinLee, Wonho
Issue Date
5월-2016
Publisher
KOREAN PHYSICAL SOC
Keywords
Neutron-scatter camera; MLEM
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.68, no.9, pp.1126 - 1131
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
68
Number
9
Start Page
1126
End Page
1131
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/88780
DOI
10.3938/jkps.68.1126
ISSN
0374-4884
Abstract
Neutron energy emitted from special nuclear materials (SNMs) can be measured by using neutronproton scattering; also, the scattering angle can be calculated from the ratio of the scattered energy to the incident energy. By using position and energy information, we can image the original source position by using the backprojection and list-mode maximum-likelihood expectation maximization (MLEM) method. In this paper, we propose an inner-crystal neutron scatter camera system in which the detectors are not separated to obtain interactions at a variety of scatter angles; based on this system, we analyzed the characteristics of the corresponding neutron-scattering camera. The factors that affected the neutron-scatter image were the neutron velocity after scattering, the cut-off level of the time of flight (ToF), and the width of the cones used for image reconstruction. To determine the optimal point for the reconstruction of an image, we estimated the performance of the system by using the figure of merit (FoM). The optimal neutron-velocity (d/ToF) was similar to 0.3 x 10(7) m/s according to our simulation result, while the optimal cut-off level of the ToF was 4 ns as the latter minimized the noise while maintaining the required efficiency. The widths of the cones (epsilon) also affected the full width at half maximum (FWHM) and the noise of the image. In terms of a simple source-geometry, whereby concepts such as "point source" were used, a large e value was suitable to achieve noise reduction; however, regarding the complicated source geometry, a small e value was favorable for precise reconstruction of the original source geometry for both the backprojection and the list-mode MLEM methods.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won ho photo

Lee, Won ho
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE