Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fire resistance of double-skinned composite tubular columns including concrete confinement

Authors
Won, Deok HeeHan, Taek HeeKim, SeungjunKang, Young Jong
Issue Date
4월-2016
Publisher
SPRINGER
Keywords
DSCT; Fire resistance; Confining effect; Column; ISO-834; Inner tube
Citation
MATERIALS AND STRUCTURES, v.49, no.4, pp.1269 - 1284
Indexed
SCIE
SCOPUS
Journal Title
MATERIALS AND STRUCTURES
Volume
49
Number
4
Start Page
1269
End Page
1284
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/89154
DOI
10.1617/s11527-015-0575-9
ISSN
1359-5997
Abstract
Double-skinned composite tubular (DSCT) columns consisting of concrete cast between outer and inner tubes have been developed to overcome certain limitations of other columns, such as the large self-weight of concrete-filled tubular columns and lack of concrete confinement of hollow concrete-filled tubular columns. The strength and ductility of the column are enhanced by the continuous confining stress provided by the inner tube. Their excellent structural performances make them particularly suitable for applications in high-rise buildings. However, if a high-rise building is damaged by fire, the economic costs associated with building repair can be high. It is very important to put the fire-damaged building back into service with the minimum post-fire repair. Thus, to predict the status of a structure under fire, its behavior should be evaluated based on the fire duration. Studies on the fire resistance of DSCT columns have been carried out for this purpose. However, they have involved the performance of the entire system without considering the effects of the DSCT column's components on the fire resistance. In this paper, the behavior of a DSCT column is investigated under an ISO-834 standard fire using an analytical method. The evaluation method for the fire resistance of a DSCT column utilizes a thermal analysis and Eurocode. In addition, the relationship between the DSCT column's components and the fire resistance is investigated, considering the confining effect. Moreover, the behavior of the DSCT column is evaluated through parametric studies of the hollow ratio, thickness of the outer tube, and thickness of the inner tube.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Young Jong photo

Kang, Young Jong
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE