Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Bioresorbable silicon electronic sensors for the brain

Authors
Kang, Seung-KyunMurphy, Rory K. J.Hwang, Suk-WonLee, Seung MinHarburg, Daniel V.Krueger, Neil A.Shin, JihoGamble, PaulCheng, HuanyuYu, SooyounLiu, ZhuangjianMcCall, Jordan G.Stephen, ManuYing, HanzeKim, JeonghyunPark, GayoungWebb, R. ChadLee, Chi HwanChung, SangjinWie, Dae SeungGujar, Amit D.Vemulapalli, BharatKim, Albert H.Lee, Kyung-MiCheng, JianjunHuang, YounggangLee, Sang HoonBraun, Paul V.Ray, Wilson Z.Rogers, John A.
Issue Date
4-Feb-2016
Publisher
NATURE PUBLISHING GROUP
Citation
NATURE, v.530, no.7588, pp.71 - +
Indexed
SCIE
SCOPUS
Journal Title
NATURE
Volume
530
Number
7588
Start Page
71
End Page
+
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/89543
DOI
10.1038/nature16492
ISSN
0028-0836
Abstract
Many procedures in modern clinical medicine rely on the use of electronic implants in treating conditions that range from acute coronary events to traumatic injury(1,2). However, standard permanent electronic hardware acts as a nidus for infection: bacteria form biofilms along percutaneous wires, or seed haematogenously, with the potential to migrate within the body and to provoke immune-mediated pathological tissue reactions(3,4). The associated surgical retrieval procedures, meanwhile, subject patients to the distress associated with re-operation and expose them to additional complications(5-8). Here, we report materials, device architectures, integration strategies, and in vivo demonstrations in rats of implantable, multifunctional silicon sensors for the brain, for which all of the constituent materials naturally resorb via hydrolysis and/or metabolic action(9-12), eliminating the need for extraction. Continuous monitoring of intracranial pressure and temperature illustrates functionality essential to the treatment of traumatic brain injury(2,13); the measurement performance of our resorbable devices compares favourably with that of non-resorbable clinical standards. In our experiments, insulated percutaneous wires connect to an externally mounted, miniaturized wireless potentiostat for data transmission. In a separate set-up, we connect a sensor to an implanted (but only partially resorbable) data-communication system, proving the principle that there is no need for any percutaneous wiring. The devices can be adapted to sense fluid flow, motion, pH or thermal characteristics, in formats that are compatible with the body's abdomen and extremities, as well as the deep brain, suggesting that the sensors might meet many needs in clinical medicine.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > KU-KIST Graduate School of Converging Science and Technology > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Kyung Mi photo

Lee, Kyung Mi
Department of Biomedical Sciences
Read more

Altmetrics

Total Views & Downloads

BROWSE