Self-Adhesive and Capacitive Carbon Nanotube-Based Electrode to Record Electroencephalograph Signals From the Hairy Scalp
- Authors
- Lee, Seung Min; Kim, Jeong Hun; Park, Cheolsoo; Hwang, Ji-Young; Hong, Joung Sook; Lee, Kwang Ho; Lee, Sang Hoon
- Issue Date
- 1월-2016
- Publisher
- IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
- Keywords
- Adhesive electrode; brain-computer interface (BCI); capacitive measurement; carbon nanotube (CNT); electroencephalography (EEG)
- Citation
- IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, v.63, no.1, pp.138 - 147
- Indexed
- SCIE
SCOPUS
- Journal Title
- IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
- Volume
- 63
- Number
- 1
- Start Page
- 138
- End Page
- 147
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/89969
- DOI
- 10.1109/TBME.2015.2478406
- ISSN
- 0018-9294
- Abstract
- We fabricated a carbon nanotube (CNT)/adhesive polydimethylsiloxane (aPDMS) composite-based dry electroencephalograph (EEG) electrode for capacitive measuring of EEG signals. As research related to brain-computer interface applications has advanced, the presence of hairs on a patient's scalp has continued to present an obstacle to recorder EEG signals using dry electrodes. The CNT/aPDMS electrode developed here is elastic, highly conductive, self-adhesive, and capable of making conformal contact with and attaching to a hairy scalp. Onto the conductive disk, hundreds of conductive pillars coated with Parylene C insulation layer were fabricated. A CNT/aPDMS layer was attached on the disk to transmit biosignals to the pillar. The top of disk was designed to be solderable, which enables the electrode to connect with a variety of commercial EEG acquisition systems. The mechanical and electrical characteristics of the electrode were tested, and the performances of the electrodes were evaluated by recording EEGs, including alpha rhythms, auditory-evoked potentials, and steadystate visually-evoked potentials. The results revealed that the electrode provided a high signal-to-noise ratio with good tolerance for motion. Almost no leakage current was observed. Although preamplifiers with ultrahigh input impedance have been essential for previous capacitive electrodes, the EEGs were recorded here by directly connecting a commercially available EEG acquisition system to the electrode to yield high-quality signals comparable to those obtained using conventional wet electrodes.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.