Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Combined Use of Malaria Antigen and Antibody Enzyme-Linked Immunosorbent Assay for Blood Screening of Plasmodium vivax in the Republic of Korea

Authors
Kim, JeeyongJang, Jin WooKim, Ju YeonOh, Deok JaLim, Chae Seung
Issue Date
2016
Publisher
KARGER
Keywords
Malaria; Plasmodium vivax; Plasmodium lactate dehydrogenase; ELISA; Antibody
Citation
MEDICAL PRINCIPLES AND PRACTICE, v.25, no.3, pp.212 - 218
Indexed
SCIE
SCOPUS
Journal Title
MEDICAL PRINCIPLES AND PRACTICE
Volume
25
Number
3
Start Page
212
End Page
218
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/90283
DOI
10.1159/000444144
ISSN
1011-7571
Abstract
Objective: To evaluate the clinical sensitivity and specificity of the newly developed Genedia malaria antigen enzymelinked immunosorbent assay (ELISA) test and to evaluate the diagnostic efficiency of the combined use of the Genedia malaria antigen and antibody ELISA tests to detect Plasmodium vivax in blood samples. Materials and Methods: In all, 1,070 samples were analyzed: 300 P. vivax-infected patients, 41 samples from posttreatment patients upon follow-up and 729 healthy volunteers. The Genedia malaria antigen ELISA test and the Genedia malaria antibody ELISA 2.0 test were evaluated and compared to polymerase chain reaction and microscopy. Results: The Genedia malaria antigen ELISA test had a clinical sensitivity of 94.7% (284/300) and a clinical specificity of 99.3% (724/729). The Genedia malaria antibody ELISA 2.0 test had a clinical sensitivity of 94.0% (282/300) and a clinical specificity of 98.4% (717/729). The Genedia malaria antigen ELISA test was able to detect 13 confirmed P. vivax cases without antibodies against P. vivax, whereas the Genedia malaria antibody ELISA 2.0 test detected 11 confirmed P. vivax cases nonreactive to the Genedia malaria antigen ELISA test, and 25 cases from 41 follow-up samples nonreactive in the Genedia malaria antigen ELISA test. The combined Genedia malaria antigen and antibody ELISA 2.0 tests had a clinical sensitivity of 98.3% (295/300) and a clinical specificity of 97.9% (714/729). Conclusion: The combination of antigen and antibody ELISAs improved the diagnostic sensitivity in P. vivax-confirmed cases in the Republic of Korea. (C) 2016 S. Karger AG, Basel
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Chae Seung photo

Lim, Chae Seung
Department of Biomedical Sciences
Read more

Altmetrics

Total Views & Downloads

BROWSE