수처리 교반기의 프로펠러 허브 볼텍스 제어Control of Propeller Hub Vortex for Water Treatment Mixer
- Other Titles
- Control of Propeller Hub Vortex for Water Treatment Mixer
- Authors
- 김대한; 문영준
- Issue Date
- 2016
- Publisher
- 한국유체기계학회
- Keywords
- CFD(전산유체역학); Water Treatment Mixer(수처리 교반기); PBCF(프로펠러 보스 캡 핀); Hub Vortex(허브 볼텍스)
- Citation
- 한국유체기계학회 논문집, v.19, no.2, pp.11 - 15
- Indexed
- KCI
- Journal Title
- 한국유체기계학회 논문집
- Volume
- 19
- Number
- 2
- Start Page
- 11
- End Page
- 15
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/90877
- DOI
- 10.5293/kfma.2016.19.2.011
- ISSN
- 2287-9706
- Abstract
- In this study, the generation of the propeller hub vortex was analyzed and a PBCF(Propeller Boss Cap Fins) was designed to control the propeller hub vortex. A RANS(Reynolds-averaged Navier-stokes) approach is employed to predict the hub vortex characteristics. The hub profile is an important factor but only a small increase (1.9%) of efficiency was obtained with the hub profile modification. The propeller hub vortex was eliminated by installing the PBCF and as a result, the propeller efficiency was increased by 5.6%.