Evaluation of a Rapid Immunochromatographic Treponemal Antibody Test Comparing the Treponema Pallidum Particle Agglutination Assay

Authors
Lee, Jong-HanLim, Chae SeungLee, Min-GeolKim, Hyon-Suk
Issue Date
Sep-2015
Publisher
WILEY
Keywords
Syphilis; rapid immunochromatographic test; Treponema pallidum particle agglutination (TPPA); agreement
Citation
JOURNAL OF CLINICAL LABORATORY ANALYSIS, v.29, no.5, pp.383 - 386
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF CLINICAL LABORATORY ANALYSIS
Volume
29
Number
5
Start Page
383
End Page
386
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/92659
DOI
10.1002/jcla.21783
ISSN
0887-8013
Abstract
Background: In addition to conventional tests, several methods for detection of treponema-specific antibodies in clinical settings have been recently introduced. We aim to comparatively evaluate a rapid immunochromatographic test (ICT) for Treponema pallidum specific antibody (SD Bioline Syphilis 3.0) and the T. pallidum particle agglutination (TPPA) assay. Methods: In all, 132 serum samples from 78 syphilis patients and 54 syphilis-negative controls were analyzed. SD Bioline Syphilis 3.0 test (Standard Diagnostic, Inc., Yongin, Korea) was evaluated and compared to Serodia TPPA assay (Fujirebio, Inc., Tokyo, Japan). All discrepant results between the two assays were repeatedly tested and evaluated by the fluorescent treponemal antibody-absorption (FTA-ABS) assay. Test reproducibility and 95% limit of detection of SD Bioline Syphilis 3.0 were determined across three different lots for seven consecutive days in triplicate. Interference due to autoantibodies and pregnancy was also tested. Results:Percent agreement between SD Bioline Syphilis 3.0 and TPPA assays was 99.2%. Sensitivity and specificity were 100%, respectively. In TPPA assay, test-to-test, day-to-day, and lot-to-lot variations were not identified until 1:320 titer (eightfold dilutions). There was no interference due to the presence of antinuclear antibodies or samples or pregnancy. Conclusions: Percent agreement of SD Syphilis 3.0 and TPPA was very good. Sensitivity and specificity were appropriate for T. pallidum antibody detection. Thus, a rapid ICT could be suitable for syphilis antibody detection. (C) 2014 Wiley Periodicals, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Chae Seung photo

Lim, Chae Seung
Department of Biomedical Sciences
Read more

Altmetrics

Total Views & Downloads

BROWSE