Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Preliminary Study of the Dosimetric Characteristics of 3D-printed Materials with Megavoltage Photons

Authors
Jeong, SeonghoonYoon, MyonggeunChung, Weon KuuKim, Dong Wook
Issue Date
7월-2015
Publisher
KOREAN PHYSICAL SOC
Keywords
3D-printer; Radiotherapy; Compensator; Immobilizer; PLA
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.67, no.1, pp.189 - 194
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
67
Number
1
Start Page
189
End Page
194
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/93066
DOI
10.3938/jkps.67.189
ISSN
0374-4884
Abstract
These days, 3D-printers are on the rise in various fields including radiation therapy. This preliminary study aimed to estimate the dose characteristics of 3D-printer materials that could be used as compensators or immobilizers in radiation treatment. The cubes with length of 5 cm and different densities of 50%, 75% and 100% were printed by using a 3D-printer. Planning CT scans of the cubes were performed by using a CT simulator (Brilliance CT, Philips Medical System, Netherlands). Dose distributions behind the cube were calculated after a 6 MV photon beam had passed through the cube. The dose responses for the 3D-printed cube, air and water were measured by using EBT3 film and a 2D array detector. When the results of air case were normalized to 100, the dose calculated by the TPS and the measured doses to 50% and 75% cube were of the 96 similar to 99. The measured and the calculated doses to water and to 100% of the cube were 82 similar to 84. The HU values for the 50%, 75% and 100% density cases were -910, -860 and -10, respectively. The dose characteristics of the 50% and the 75% products were similar to that of air while the 100% product seemed to be similar to that of water. This information will provide guidelines for making an immobilization tool that can play the role of a compensator and for making a real human phantom that can exactly describe the inside of the human body. This study was necessary for Poly Lactic Acid (PLA) based 3D-printer users who are planning to make something related to radiation therapy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Myong geun photo

Yoon, Myong geun
보건과학대학 (바이오의공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE