Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effect of effective lens position on cylinder power of toric intraocular lenses

Authors
Eom, YoungsubKang, Su-YeonSong, Jong SukKim, Yong YeonKim, Hyo Myung
Issue Date
2월-2015
Publisher
CANADIAN OPHTHAL SOC
Citation
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, v.50, no.1, pp.26 - 32
Indexed
SCIE
SCOPUS
Journal Title
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE
Volume
50
Number
1
Start Page
26
End Page
32
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/94515
DOI
10.1016/j.jcjo.2014.08.003
ISSN
0008-4182
Abstract
Objective: To evaluate the effects of effective lens position (ELF) on the corneal plane effective cylinder power of toric intraocular lenses (IOLs). Design: Retrospective cross-sectional study. Participants: Ninety-four eyes from 78 patients who underwent uncomplicated phacoemulsification with implantation of an AcrySof toric IOL (1.50- to 3.00-D cylinder). Methods: The amount of corneal plane effective cylinder power of toric 10Ls given by the manufacturer (target-induced astigmatism vector [VIA]) was compared with the postoperatively achieved cylindrical correction (surgically induced astigmatism vector [SIA]). The theoretical corneal plane cylinder power of toric IOLs was calculated according to ELF and corneal power using a refractive vergence formula. Results: The TIA (1.59 +/- 0.43 D) was significantly smaller than the SIA (1.78 +/- 0.65 D; p < 0.001). The difference between the magnitudes of SIA and TIA demonstrated a significant negative correlation with ELF (r = -0.219 and p = 0.034). The theoretical corneal plane cylinder power of toric IOLs demonstrated a decreasing trend as the ELF and corneal power increased. The range of changes in corneal plane effective cylinder power according to ELF and corneal power was greater in toric IOLs with high toricity. Conclusions: The cylinder power of AcrySof toric IOLs should be adjusted according to ELF. For eyes with small ELF, the cylinder power should be reduced, and for eyes with large ELF, the cylinder power should be increased. The amount of reducing or increasing cylinder power of toric IOLs should be increased as the toricity increases.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE