Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

FI-HG-AAS를 이용한 전처리 과정에서 사용되는 예비환원제의 종류에 따른 요중 비소 분석결과 비교Comparisons of Urinary Arsenic Analysis by Pre-reductant for Preconditioning via the FI-HG-AAS Method

Other Titles
Comparisons of Urinary Arsenic Analysis by Pre-reductant for Preconditioning via the FI-HG-AAS Method
Authors
최승현최재욱조용민배문주
Issue Date
2015
Publisher
한국환경보건학회
Keywords
Hydride Generation atomic absorption spectrometry; KI/ascorbic acid; L-cysteine; Pre-reductant; Urinary arsenic
Citation
한국환경보건학회지, v.41, no.5, pp.289 - 298
Indexed
KCI
Journal Title
한국환경보건학회지
Volume
41
Number
5
Start Page
289
End Page
298
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/95233
ISSN
1738-4087
Abstract
Objectives: The method of analyzing urinary arsenic by flow injection hydride generation atomicabsorption spectrometry (FI-HG-AAS) is generally used because it shows relatively greater sensitivity, lowdetection limits, low blocking action, and is simple to operate. In this study, the results of analysisaccording to three pre-reductants commonly used in the FI-HG-AAS method were compared with eachother. Methods: To analyze urinary arsenic, nineteen urine samples were collected from adults aged 43-79 years oldwithout occupational arsenic exposure. Analysis equipment was FI-HG-AAS (AAnalyst 800/FIAS 400, Perkin-Elmer Inc., USA). The three pre-reductants were potassium iodide (KI/AA), C3H7NO2S (L-cysteine), and amixture of KI/AA and L-cysteine (KI/AA&L-cysteine). Results: In the results of the analysis, the recovery rate of the method using KI/AA was 82.3%, 95.7% for Lcysteine,and 123.5% for KI/AA and L-cysteine combined. When compared with the results by use of highperformance liquid chromatography inductively-coupled plasma mass spectrometry (HPLC-ICP-MS), themethod using L-cysteine was the closest to those using HPLC-ICP-MS (98.57 μg/L for HPLC-ICP-MS; 74.96μg/L for L-cysteine; 69.23 μg/L for KI/AA and L-cysteine; 13.06 μg/L for KI/AA) and were significantlycorrelated (R2=0.882). In addition, they showed the lowest coefficient of variation in the results between twolaboratories that applied the same method. Conclusion: The efficiency of hydride generation is considered highly important to the analysis of urinaryarsenic via FI-HG-AAS. This study suggests that using L-cysteine as a pre-reductant may be suitable and themost rational among the FI-Hg-AAS methods using pre-reductants.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Jae Wook photo

Choi, Jae Wook
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE