PCM 유닛을 적용한 공기 열원 히트펌프의 연속난방 성능 특성에 관한 실험적 연구An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating
- Other Titles
- An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating
- Authors
- 장민; 정동일; 정종호; 김용찬
- Issue Date
- 2015
- Publisher
- 대한설비공학회
- Keywords
- PCM(상변화물질); Defrosting(제상); Continuous heating(연속난방)
- Citation
- 설비공학 논문집, v.27, no.10, pp.537 - 543
- Indexed
- KCI
- Journal Title
- 설비공학 논문집
- Volume
- 27
- Number
- 10
- Start Page
- 537
- End Page
- 543
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/95749
- DOI
- 10.6110/KJACR.2015.27.10.537
- ISSN
- 1229-6422
- Abstract
- Air-source heat pumps are widely used in winter as heating units due to their higher efficiency compared to electronic heaters or gas fired equipment. However, the air-source heat pump can cause discomfort during periodic defrosting operations. In this study, a PCM unit for continuous heating was adopted to solve this problem. The PCM unit consisted of a PCM, a heat exchanger, and control valves. It was installed between the outdoor and indoor units. The performance of the proposed system was measured during both defrosting and heating operations. The indoor unit showed an average leaving temperature of 26℃ after adopting the PCM unit for continuous heating during the defrosting operation.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > Department of Mechanical Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.