Complications of the Intramedullary Skeletal Kinetic Distractor (ISKD) in Distraction Osteogenesis

Authors
Lee, Dong HoonRyu, Keun JungSong, Hae RyongHan, Soo-Hong
Issue Date
Dec-2014
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Citation
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, v.472, no.12, pp.3852 - 3859
Indexed
SCIE
SCOPUS
Journal Title
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
Volume
472
Number
12
Start Page
3852
End Page
3859
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/96559
DOI
10.1007/s11999-014-3547-4
ISSN
0009-921X
Abstract
Background The Intramedullary Skeletal Kinetic Distractor (ISKD) (Orthofix Inc, Lewisville, TX, USA) is an intramedullary device designed for more comfortable limb lengthening than that with external fixators; lengthening is achieved with this nail using rotational oscillation between two telescoping sections. However, the degree to which this device achieves this goal and its complication rate have not been fully documented. Questions/purposes We determined (1) the frequency with which distraction was not achieved at the desired rate, (2) whether pain differed between patients with normally and abnormally distracting nails, (3) risk factors for abnormal nails, and (4) other complications. Methods Weanalyzed 35 lengthening segments (26 femurs, nine tibias) in 19 patients. Mean length achieved was 47 mm. Femoral nails were categorized into four groups according to distraction rate: normal, runaway (unintentionally faster rate [>1.5 mm/day]), difficult-to-distract (slower rate [< 0.8 mm/day] requiring manual manipulation but not requiring general anesthesia), and nondistracting (slower rate [< 0.8 mm/day] requiring manual manipulation under general anesthesia or reosteotomy). Possible risk factors, including age, BMI, preoperative thigh circumferences, degree of intramedullary overreaming, and length of the thicker portion of the nail within the distal fragment, were compared among groups. VAS pain scores were compared among groups under three conditions: rest, physiotherapy, and distraction motion. Complications were also analyzed. Minimum followup was 15 months (mean, 26 months; range, 15-38 months) after first-stage surgery. Results Abnormal distraction rate was observed in 21 of 35 segments (60%; 17 femurs, four tibias). VAS pain scores showed no differences among groups during rest or physiotherapy but were higher (p = 0.02) in the problematic nails (7-8 points) versus normal nails (3 points) during distraction. Only mean length of the thicker portion of the nail within the distal fragment differed between normally and abnormally distracting nails (95 mm versus 100 mm; p = 0.03), although this was unlikely to be clinically important. Complications occurred in 10 patients (53%), including five with decreased ankle ROM during distraction, four with delayed bone healing, and one with mechanical device failure during distraction. Conclusions Rate control was difficult to achieve with the ISKD nail for femoral and tibial lengthenings, complications were relatively common, and among patients in whom rate control was not achieved, pain levels were high. Based on our findings, we believe that surgeons should avoid use of this nail.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE