Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A prospective study on the effectiveness of newly developed autogenous tooth bone graft material for sinus bone graft procedure

Authors
Jun, Sang-HoAhn, Jin-SooLee, Jae-IlAhn, Kyo-JinYun, Pi-YoungKim, Young-Kyun
Issue Date
12월-2014
Publisher
KOREAN ACAD PROSTHODONTICS
Keywords
Tooth; Bio-Oss; Sinus
Citation
JOURNAL OF ADVANCED PROSTHODONTICS, v.6, no.6, pp.528 - 538
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF ADVANCED PROSTHODONTICS
Volume
6
Number
6
Start Page
528
End Page
538
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/96625
DOI
10.4047/jap.2014.6.6.528
ISSN
2005-7806
Abstract
PURPOSE. The purpose of this prospective study was to evaluate the effectiveness of newly developed autogenous tooth bone graft material (AutoBT)application for sinus bone graft procedure. MATERIALS AND METHODS. The patients with less than 5.0 mm of residual bone height in maxillary posterior area were enrolled. For the sinus bone graft procedure, Bio-Oss was grafted in control group and AutoBT powder was grafted in experimental group. Clinical and radiographic examination were done for the comparison of grafted materials in sinus cavity between groups. At 4 months after sinus bone graft procedure, biopsy specimens were analyzed by microcomputed tomography and histomorphometric examination for the evaluation of healing state of bone graft site. RESULTS. In CT evaluation, there was no difference in bone density, bone height and sinus membrane thickness between groups. In microCT analysis, there was no difference in total bone volume, new bone volume,. bone mineral density of new bone between groups. There was significant difference trabecular thickness (0.07 mu m in Bio-Oss group Vs. 0.08 mu m in AutoBT group) (P=.006). In histomorphometric analysis, there was no difference in new bone formation, residual graft material, bone marrow space between groups. There was significant difference osteoid thickness (8.35 mu m in Bio-Oss group Vs. 13.12 mu m in AutoBT group) (P=.025). CONCLUSION. AutoBT could be considered a viable alternative to the autogenous bone or other bone graft materials in sinus bone graft procedure.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE