The influence of shading control strategies on the visual comfort and energy demand of office buildings

Authors
Yun, GyeongYoon, Kap ChunKim, Kang Soo
Issue Date
12월-2014
Publisher
ELSEVIER SCIENCE SA
Keywords
Shading control strategy; Visual comfort; Energy demand; Venetian blind; EnergyPlus
Citation
ENERGY AND BUILDINGS, v.84, pp.70 - 85
Indexed
SCIE
SCOPUS
Journal Title
ENERGY AND BUILDINGS
Volume
84
Start Page
70
End Page
85
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/96686
DOI
10.1016/j.enbuild.2014.07.040
ISSN
0378-7788
Abstract
A lighting control strategy using daylighting is important to reduce energy consumption, and to provide occupants with visual comfort. The objective of this research is to evaluate visual comfort and building energy demand, and suggest lighting and shading control strategies for visual comfort and building energy savings. This research intends to achieve visual comfort and energy savings in an office building, by means of visual environmental control, and focuses on a quantitative criterion (illuminance), and a qualitative criterion (glare index) in daylighting. We used HDR images captured in real scene and simulation (DIVA-for-Rhino) for glare evaluation. The measured data from the mock-up room and the scale model were compared, to validate the simulation tool. Vertical eye illuminance (E-nu) is recommended for the glare index, in place of the DGI or DGP. To prevent disturbing glare and to secure maximum daylight, control strategies of lighting and shading are suggested, related to the E-nu value. In addition, the EnergyPlus program was used for calculation of the annual energy consumption. Building energy consumption is presented according to three building orientations, and 10 control strategies of lighting and shading. If there is no need to consider glare, a blind slat angle of 0 degrees or dynamic shading is better in winter, regardless of the building orientation. In summer, a blind slat angle of 30 degrees (static angle) or dynamic shading is suitable for an energy efficient and anti-glare control strategy. (C) 2014 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE