Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Characterization of indoor air quality and efficiency of air purifier in childcare centers, Korea

Authors
Oh, Hyeon-JuNam, In-SickYun, HyunjunKim, JinmanYang, JinhoSohn, Jong-Ryeul
Issue Date
Dec-2014
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Particulate matter; Childcare center; Bio-aerosol; Correlation coefficient; Air purifier
Citation
BUILDING AND ENVIRONMENT, v.82, pp.203 - 214
Indexed
SCIE
SCOPUS
Journal Title
BUILDING AND ENVIRONMENT
Volume
82
Start Page
203
End Page
214
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/96708
DOI
10.1016/j.buildenv.2014.08.019
ISSN
0360-1323
Abstract
Particulate matter (PM) samples were collected from inside ten childcare centers, and from their adjacent outdoor environments in Seoul, Korea during the summer, autumn and winter seasons. The concentrations and distribution of microbial size of the airborne bacteria and fungi in bin-aerosols were also investigated. The average indoor concentrations of fine particles less than 2.5 mu m (PM2.5) in the residential areas ranged from 37.1 mu g/m(3) (+/- 5.8 mu g/m(3)) to 45.2 mu g/m(3) (+/- 5.3 mu g/m(3)), while indoor PM2.5 concentrations in centers with roadways nearby ranged from 48.9 mu g/m(3) (+/- 9.5 mu g/m(3)) to 52.9 mu g/m(3) (+/- 7.7 mu g/m(3)), and up to 51.1 mu g/m(3) (+/- 6.4 mu g/m(3)) in residential areas located near construction sites. The concentrations of particulate matter indoor in childcare centers were correlated with the corresponding outdoor locations, in residential areas (R-2 of 0.64 for PM10 and 0.66 for PM2.5), near roadways (R-2 of 0.72 for PM10 and 0.76 for PM2.5), and near construction areas (R-2 of 0.45 for PM10 and 0.62 for PM2.5). The distribution of bin-aerosols showed that 69.4% to 78.1% of the airborne bacteria in the outdoor environments existed in stages 1-3 (over 3.3 mu m), while from 59.2% to 78.6% existed in stages 2-4 (2.1 -7.0 mu m) inside the childcare centers. When the efficiency of air purifiers was compared with the location and characteristics of the indoor of child care centers, the removal efficiency of particulate matter with new data that may characterize indoor air quality. (C) 2014 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE