Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

No correlation between joint position sense and force sense for measuring ankle proprioception in subjects with healthy and functional ankle instability

Authors
Kim, Chang-YongChoi, Jong-DukKim, Hyeong-Dong
Issue Date
11월-2014
Publisher
ELSEVIER SCI LTD
Keywords
Ankle proprioception; Force sense; Functional ankle instability; Joint position sense
Citation
CLINICAL BIOMECHANICS, v.29, no.9, pp.977 - 983
Indexed
SCIE
SCOPUS
Journal Title
CLINICAL BIOMECHANICS
Volume
29
Number
9
Start Page
977
End Page
983
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/96910
DOI
10.1016/j.clinbiomech.2014.08.017
ISSN
0268-0033
Abstract
Background: In general, ankle proprioception is most often evaluated by assessing joint position sense and force sense. However, in contrast to observational studies of joint position sense and force sense, no studies have examined the correlations between joint position sense and force sense. Therefore, the objective of this study was to investigate the correlations between joint position sense and force sense in subjects with healthy and functional ankle instability. Methods: Of the sixty nine subjects enrolled in the cross-sectional laboratory study, 35 had functional ankle instability and 34 were healthy subjects. Angle reproduction and force matching methods were used to quantify joint position sense and force sense of the ankle proprioception. These methods were also measured by using a flexible twin axis electrogoniometer and linear force, respectively. Three trials were performed at each angle and force. And then, absolute errors were calculated. Findings: Significant differences between the functional ankle instability and healthy group were found for absolute errors of plantar flexion, dorsiflexion, inversion, and eversion (P < 0.05). No significant correlations between the joint position sense and force sense were found in subjects with both healthy, except for absolute errors of the eversion (r = 0.652, P < 0.05, r(2) = 0.425), and functional ankle instability group (P > 0.05). Interpretation: These findings suggest that it could be explained for deficits of ankle proprioception when angle reproduction and force matching tests to quantify joint position sense and force sense were applied and presented at the same time, not individually. (C) 2014 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyeong Dong photo

Kim, Hyeong Dong
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE