Slime thickness evaluation of bored piles by electrical resistivity probe

Authors
Chun, Ok-HyunYoon, Hyung-KooPark, Min-ChulLee, Jong-Sub
Issue Date
9월-2014
Publisher
ELSEVIER SCIENCE BV
Keywords
Bored pile; Electrical resistivity probe; Field test; Layer detection; Slime; TDR
Citation
JOURNAL OF APPLIED GEOPHYSICS, v.108, pp.167 - 175
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF APPLIED GEOPHYSICS
Volume
108
Start Page
167
End Page
175
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/97479
DOI
10.1016/j.jappgeo.2014.07.004
ISSN
0926-9851
Abstract
The bottoms of bored piles are generally stacked with soil particles, both while boreholes are being drilled, and afterward. The stacked soils are called slime, and when loads are applied on the pile, increase the pile settlement. Thus to guarantee the end bearing capacity of bored piles, the slime thickness should be precisely detected. The objective of this study is to suggest a new method for evaluating the slime thickness, using temperature compensated electrical resistivity. Laboratory studies are performed in advance, to estimate and compare the resolution of the electrical resistivity probe (ERP) and time domain reflectometry (TDR). The electrical properties of the ERP and TDR are measured using coaxial type electrodes and parallel type two-wire electrodes, respectively. Penetration tests, conducted in the fully saturated sand-clay mixtures, demonstrate that the ERP produces a better resolution of layer detection than TDR. Thus, field application tests using the ERP with a diameter of 35.7 mm are conducted for the investigation of slime thickness in large diameter bored piles. Field tests show that the slime layers are clearly identified by the ERP: the electrical resistivity dramatically increases at the interface between the slurry and slime layer. The electrical resistivity in the slurry layer inversely correlates with the amount of circulated water. This study suggests that the new electrical resistivity method may be a useful method for the investigation of the slime thickness in bored piles. (C) 2014 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles