Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fast Responding Exhaled-Breath Sensors Using WO3 Hemitubes Functionalized by Graphene-Based Electronic Sensitizers for Diagnosis of Diseases

Authors
Choi, Seon-JinFuchs, FranzDemadrille, RenaudGrevin, BenjaminJang, Bong-HoonLee, Seo-JinLee, Jong-HeunTuller, Harry L.Kim, Il-Doo
Issue Date
25-6월-2014
Publisher
AMER CHEMICAL SOC
Keywords
diagnosis of diseases; exhaled breath sensor; electrospinning; WO3 hemitube; graphene
Citation
ACS APPLIED MATERIALS & INTERFACES, v.6, no.12, pp.9061 - 9070
Indexed
SCIE
SCOPUS
Journal Title
ACS APPLIED MATERIALS & INTERFACES
Volume
6
Number
12
Start Page
9061
End Page
9070
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/98201
DOI
10.1021/am501394r
ISSN
1944-8244
Abstract
Diagnostic sensing device using exhaled breath of human have critical advantages due to the noninvasive diagnosis and high potential for portable device with simple analysis process. Here, we report ultrafast as well as highly sensitive bumpy WO3 hemitube nanostructure assisted by O-2 plasma surface modification with functionalization of graphene-based material for the detection of acetone (CH3COCH3) and hydrogen sulfide (H2S) which are biomarkers for the diagnosis of diabetes and halitosis, respectively. 0.1 wt % graphene oxide (GO)- and 0.1 wt % thin layered graphite (GR)- WO3 hemitube composites showed response times of 11.5 +/- 2.5 s and 13.5 +/- 3.4 s to 1 ppm acetone as well as 12.5 +/- 1.9 s and 10.0 +/- 1.6 s to 1 ppm of H2S, respectively. In addition, low limits of detection (LOD) of 100 ppb (R-air/R-gas = 1.7 for acetone and R-air/R-gas, = 3.3 for H2S at 300 C degrees) were achieved. The superior sensing properties were ascribed to the electronic sensitization of graphene based materials by modulating space charged layers at the interfaces between n-type WO3 hemitubes and p-type graphene based materials, as identified by Kelvin Probe Force Microscopy (KPFM). Rapid response and superior sensitivity of the proposed sensing materials following cyclic thermal aging demonstrates good potential for real-time exhaled breath diagnosis of diseases.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Materials Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE