Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Optimization of a multiple-scattering Compton camera as a photon-tracking imager for 6-MV photon therapy

Authors
Lee, TaewoongYoon, ChangyeonLee, Wonho
Issue Date
6월-2014
Publisher
KOREAN PHYSICAL SOC
Keywords
Compton camera; Semiconductor detector; Uncertainty factor
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.64, no.11, pp.1745 - 1750
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
64
Number
11
Start Page
1745
End Page
1750
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/98459
DOI
10.3938/jkps.64.1745
ISSN
0374-4884
Abstract
During radiation therapy, the irradiated position and the energy deposited in a patient must be monitored. In general, calculations before photon exposure or 2D measurements of the transmitted photons have been widely used for making dose estimates. In this paper, we propose a real-time 3D dose measurement using Compton imaging technology. On the basis of the Monte-Carlo method, we designed a multiple-scattering Compton camera system (MSCC) with semiconductor and scintillation detectors. The MSCC was constructed with two semiconductor detectors as scattering detectors and a cadmium-tungstate (CWO) scintillator detector as an absorber detector. The two planar semiconductor arrays, and the CWO array consisted of 40 x 40 pixels, each with a size of 1 x 1 x epsilon mm(3), where epsilon is the variable thickness of the detectors. The design parameters, such as the types of semiconductors, detector thicknesses and distances between detectors, were optimized on the basis of the detection efficiency and angular resolution of reconstructed images for a point source. Under the optimized conditions, uncertainty factors in geometry and energy were estimated for various inter-detector distances. We used a source corresponding to photons scattered from a water phantom exposed to 6-MeV peak X-rays. According to our simulation results, the figure of merit, reached its maximum value when the inter-detector distance was 3 cm. In order to achieve a high FOM, we chose 1 cm as the optimum thickness for the scattering and absorbed detectors. A cadmium-zinc-telluride (CZT) detector showed the best performance among the simulated semiconductors. The position uncertainty caused by the pixelization effect was the major factor in degrading the angular resolution of the reconstructed images, and the degradation caused by energy broadening was less than expected. The angular uncertainties caused by Doppler broadening and incorrect sequencing were minimal compared with that of pixelization. Our simulation showed the feasibility of using the semiconductor-based Compton camera to monitor the exposed dose in 3D radiation therapy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won ho photo

Lee, Won ho
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE