Seasonal evaluation of bioaerosols from indoor air of residential apartments within the metropolitan area in South Korea

Authors
Moon, Kyong WhanHuh, Eun HaeJeong, Ho Chul
Issue Date
4월-2014
Publisher
SPRINGER
Keywords
Apartments' indoor air; Bioaerosols; Staphylococcus aureus; Methicillin-resistant S. aureus; Adenovirus; Seasonal influence
Citation
ENVIRONMENTAL MONITORING AND ASSESSMENT, v.186, no.4, pp.2111 - 2120
Indexed
SCIE
SCOPUS
Journal Title
ENVIRONMENTAL MONITORING AND ASSESSMENT
Volume
186
Number
4
Start Page
2111
End Page
2120
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/98810
DOI
10.1007/s10661-013-3521-8
ISSN
0167-6369
Abstract
The aims of the present study were to determine the levels of bioaerosols including airborne culturable bacteria (total suspended bacteria, Gram-positive bacteria, Staphylococcus, Staphylococcus aureus, methicillin-resistant S. aureus (MRSA), and Gram-negative bacteria), fungi, endotoxin, and viruses (influenza A, influenza B, respiratory syncytial virus types A/B, parainfluenza virus types 1/2/3, metapnemovirus, and adenovirus) and their seasonal variations in indoor air of residential apartments. Of the total suspended bacteria cultured in an indoor environment, Staphylococcus was dominant and occupied 49.0 to 61.3 % of indoor air. Among Staphylococcus, S. aureus were detected in 100 % of households' indoor air ranging from 4 to 140 CFU/m(3), and 66 % of households were positive for MRSA ranging from 2 to 80 CFU/m(3). Staphylococcus and S. aureus concentrations correlated with indoor temperature (adjusted beta: 0.4440 and 0.403, p < 0.0001). Among respiratory viruses, adenovirus was detected in 14 (14 %) samples and influenza A virus was detected in 3 (3 %) samples regarding the indoor air of apartments. Adenovirus concentrations were generally higher in winter (mean concentration was 2,106 copies/m(3)) than in spring (mean concentration was 173 copies/m(3)), with concentrations ranging between 12 and 560 copies/m(3). Also, a strong negative correlation between adenovirus concentrations and relative humidity in indoor air was observed (r = -0.808, p < 0.01). Furthermore, temperature also negatively correlated with adenovirus concentrations (r = -0.559, p < 0.05).
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Kyong Whan photo

Moon, Kyong Whan
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE