Design and Performance Investigation of a Multi-pinhole Collimator for a Small Field of View Gamma Imaging System

Authors
Bae, JaekeonBae, SeungbinLee, KisungChoi, YongKim, YongkwonJoung, Jinhun
Issue Date
4월-2014
Publisher
KOREAN PHYSICAL SOC
Keywords
Limited angle system; Nuclear medicine; Multi-pinhole collimator
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.64, no.7, pp.970 - 975
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
64
Number
7
Start Page
970
End Page
975
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/98959
DOI
10.3938/jkps.64.970
ISSN
0374-4884
Abstract
The aim of this study is to design a collimator for a gamma imaging system that has a smallfootprint, a fast-scan-time, and a organ-specific applicability. To achieve such features, the collimator must have a high resolution, a high sensitivity, and a gantry with a simple geometry. For ensuring high resolution and high sensitivity, we designed a multi-pinhole collimator. For realizing a simplified gantry, we carried out studies with limited angle reconstruction. On the designed multi-pinhole collimator has eight-pinholes, whose diameters are 2 mm. Limited-angle reconstruction has been conducted with angle intervals of 3, 6, 9, and 12 degrees and with an angle coverage of 60, 90, 120, 150, and 180 degrees. The reconstruction of an image was separately developed based on the ray-driven and voxel-driven methods in order to overcome the sampling problem and to reduce the amount of computation required. To evaluate the performance of the designed system, performed studies on three spherical phantoms and a heart phantom by using the Geant4 application for tomographic emission (GATE) simulation tool. The results showed that the full width at half maximum (FWHM) of the center source were 6.25 mm and 7.18 mm for single-pinhole and multi-pinhole collimators, respectively. Moreover, limited angle reconstruction resulted in a higher efficiency of the imaging system because it overcame the limitation of the gantry geometry. Limited-angle reconstruction was optimized at an angle coverage of 120. with an angle interval of 6 degrees, then reconstructed image was shown a 12.18 mm FWHM. This suggests that the designed system needs only one-third the number of projections to acquire a reconstructed image with a slight degradation in image quality. This also suggests that our proposed multi-pinhole collimator is suitable for applications requiring a small-footprint, a fast-scan-time, and organ-specificity.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ki sung photo

Lee, Ki sung
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE