Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

Authors
Kim, Jae-HongKim, Ki-BaekKim, Woong-ChulKim, Ji-HwanKim, Hae-Young
Issue Date
3월-2014
Publisher
KOREAN ASSOC ORTHODONTISTS
Keywords
Three-dimensional subtractive rapid prototyping; Intraoral scanning; Accuracy; Precision
Citation
KOREAN JOURNAL OF ORTHODONTICS, v.44, no.2, pp.69 - 76
Indexed
SCIE
SCOPUS
KCI
Journal Title
KOREAN JOURNAL OF ORTHODONTICS
Volume
44
Number
2
Start Page
69
End Page
76
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/99143
DOI
10.4041/kjod.2014.44.2.69
ISSN
2234-7518
Abstract
Objective: This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods: Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. Results: The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions: The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE