Rapid immuno-analytical system physically integrated with lens-free CMOS image sensor for food-borne pathogens
- Authors
- Jeon, Jin-Woo; Kim, Jee-Hyun; Lee, Jong-Mook; Lee, Won-Ho; Lee, Do-Young; Paek, Se-Hwan
- Issue Date
- 15-2월-2014
- Publisher
- ELSEVIER ADVANCED TECHNOLOGY
- Keywords
- Chemiluminescent ELISA-on-a-chip; CMOS image sensor; Portable immunosensor system; Immuno-magnetic separation; Food-borne pathogen
- Citation
- BIOSENSORS & BIOELECTRONICS, v.52, pp.384 - 390
- Indexed
- SCIE
SCOPUS
- Journal Title
- BIOSENSORS & BIOELECTRONICS
- Volume
- 52
- Start Page
- 384
- End Page
- 390
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/99280
- DOI
- 10.1016/j.bios.2013.09.004
- ISSN
- 0956-5663
- Abstract
- To realize an inexpensive, pocket-sized immunosensor system, a rapid test devise based on cross-flow immuno-chromatography was physically combined with a lens-free CMOS image sensor (CIS), which was then applied to the detection of the food-borne pathogen, Salmonella typhimurium (S. typhimurium). Two ass, each retaining 1.3 mega pixel array, were mounted on a printed circuit board to fabricate a disposable sensing module, being connectable with a signal detection system. For the bacterial analysis, a cellulose membrane-based immunosensing platform, ELISA-on-a-chip (EOC), was employed, being integrated with the CIS module, and the antigen-antibody reaction sites were aligned with the respective sensor. In such sensor construction, the chemiluminescent signals produced from the EOC are transferred directly into the sensors and are converted to electric signals on the detector. The EOC-CIS integrated sensor was capable of detecting a traceable amount of the bacterium (4.22 x 10(3) CFU/mL), nearly comparable to that adopting a sophisticated detector such as cooled-charge-coupled device, while having greatly reduced dimensions and cost. Upon coupling with immuno-magnetic separation, the sensor showed an additional 67-fold enhancement in the detection limit. Furthermore, a real sample test was carried out for fish muscles inoculated with a sample of 3.3 CFU S. typhimurium per 10 g, which was able to be detected earlier than 6 h after the onset of pre-enrichment by culture. (C) 2013 Elsevier B.V. All rights reserved.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Science and Technology > Department of Biotechnology and Bioinformatics > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.