Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Simultaneous analysis of urinary phthalate metabolites of residents in Korea using isotope dilution gas chromatography-mass spectrometry

Authors
Kim, MiokSong, Na RaeChoi, Jong-HoLee, JeongaePyo, Heesoo
Issue Date
1-Feb-2014
Publisher
ELSEVIER SCIENCE BV
Keywords
Urinary phthalate metabolites; Gas chromatography-mass spectrometry; Trimethylsilylation; Isotope dilution; Biomonitoring
Citation
SCIENCE OF THE TOTAL ENVIRONMENT, v.470, pp.1408 - 1413
Indexed
SCIE
SCOPUS
Journal Title
SCIENCE OF THE TOTAL ENVIRONMENT
Volume
470
Start Page
1408
End Page
1413
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/99319
DOI
10.1016/j.scitotenv.2013.07.037
ISSN
0048-9697
Abstract
Phthalates are used in industry products, household items, and medical tools as plasticizers. Human exposure to phthalates has raised concern about its toxicity. In the present study, optimization was conducted for the simultaneous analysis of eight kinds of phthalate metabolites using gas chromatography-mass spectrometry (GC-MS): MEP, MiBP, MnBP, MBzP, MiNP, MEHP, MEOHP, and MEHHP. In order to minimize the matrix effect and to do quantitative analysis, isotope dilution and LLE-GC-MS methods were performed. Urine samples were enzymatically hydrolyzed, extracted with a mixture of n-hexane and ethyl ether (8:2; v:v), and subsequently derivatized with trimethylsilylation. All eight kinds of analytes showed clear resolution and high reproducibility in GC-MS results. The method detection limit ranged from 0.05 ng/mL to 0.2 ng/mL. Calibration curves were found to be linear from 0.2 to 100 ng/mL with -(2) > 0.992. The relative standard deviation of the intraday precision using water and urine ranged from 2.1% to 163%. The analysis was performed with urine samples that were collected from adults residing in the Republic of Korea. The analyzed concentration results were compared according to gender and region. As a result, DEHP metabolites showed the highest detected concentration (75.92 mu g/g creatinine, 100%), and MiNP, a metabolite of DiNP, showed the lowest detected concentration (0.42 mu g/g creatinine, 22.5%). On average, female urine (200.76 mu g/g creatinine) had a higher detected concentration of Sigma(8) phthalate metabolites than male urine. Samples from rural regions (211.96 mu g/g creatinine) had higher levels than samples from urban regions. (C) 2013 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Chemistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE