Oxford phase III meniscal bearing fracture: Case report
- Authors
- Lim, Hong-Chul; Shon, Won-Yong; Kim, Seung-Ju; Bae, Ji-Hoon
- Issue Date
- 1월-2014
- Publisher
- ELSEVIER SCIENCE BV
- Keywords
- Oxford unicompartmental; Knee; Meniscal bearing; Fracture
- Citation
- KNEE, v.21, no.1, pp.340 - 342
- Indexed
- SCIE
SCOPUS
- Journal Title
- KNEE
- Volume
- 21
- Number
- 1
- Start Page
- 340
- End Page
- 342
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/99662
- DOI
- 10.1016/j.knee.2013.07.012
- ISSN
- 0968-0160
- Abstract
- Meniscal bearing fracture is a rare complication of phase III Oxford unicompartmental knee replacement (UKR). We report a case of a meniscal bearing fracture that occurred 7 years after phase III Oxford medial UKR The meniscal bearing showed uneven delamination of the polyethylene in the thinnest articular surface and an impingement lesion. This lesion initiated a fatigue crack that propagated to cause failure of the meniscal bearing. This is the first report of a meniscal bearing fracture without a posterior marker wire. (C) 2013 Elsevier B.V. All rights reserved.