Tunnel ventilation control via an actor-critic algorithm employing nonparametric policy gradients

Citations

WEB OF SCIENCE

7
Citations

SCOPUS

8

초록

The appropriate operation of a tunnel ventilation system provides drivers Passing through the tunnel,with comfortable and sale driving conditions. Tunnel ventilation involves maintaining CO pollutant concentration and VI (visibility index) under an adequate level with operating highly energy-consuming facilities Such as jet-fans. Therefore. it is significant to have an efficient operating algorithm in aspects of a safe driving environment as well as saving energy. In this research, a reinforcement learning (RL) method based on the actor-critic architecture and nonparametric policy gradients is applied as the control algorithm. The two objectives listed above, maintaining an adequate level Of Pollutants and minimizing power consumption, are included into a reward formulation that is a performance index to be maximized in the RL methodology. In this paper. a nonparametric approach is adopted as a promising route to perform a rigorous gradient search in a function space of policies to improve the efficacy of the actor module. Extensive Simulation Studies performed with real data collected front an existing tunnel system confirm that with the Suggested algorithm, the control purposes were well accomplished and improved when compared to a previously developed RL-based control algorithm.

키워드

Actor-critic architecture; Nonparametric methods; Policy search; Reinforcement learning (RL); Tunnel ventilation control; SYSTEM
제목
Tunnel ventilation control via an actor-critic algorithm employing nonparametric policy gradients
저자
Chu, Baeksuk; Hong, Daehie; Park, Jooyoung
DOI
10.1007/s12206-008-0924-5
발행일
2009-02
유형
Article
저널명
Journal of Mechanical Science and Technology
권
23
호
2
페이지
311 ~ 323