Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Cation-selective electropreconcentration

Authors
Shin, Il HyungKim, Ki-jungKim, JimanKim, Hee ChanChun, Honggu
Issue Date
2014
Publisher
ROYAL SOC CHEMISTRY
Citation
LAB ON A CHIP, v.14, no.11, pp.1811 - 1815
Indexed
SCIE
SCOPUS
Journal Title
LAB ON A CHIP
Volume
14
Number
11
Start Page
1811
End Page
1815
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/101244
DOI
10.1039/c4lc00024b
ISSN
1473-0197
Abstract
A cation-selective microfluidic sample preconcentration system is described. The cation sample was electropreconcentrated using a reversed-direction electroosmotic flow (EOF) and an anion-permselective filter, where an electric double layer (EDL) overlap condition existed. The anion-permselective filter between microchannels was fabricated by three different methods: 1) extending a positively charged, nanoporous, polymer membrane by photopolymerization of poly(diallyldimethylammonium chloride) (PDADMAC); 2) etching a nanochannel and then coating it with a positively-charged monomer, N-[3(trimethoxysilyl)propyl]-N'-(4-vinylbenzyl)ethylenediamine hydrochloride (TMSVE); and, 3) etching a nanochannel and then coating it with a positively-charged, pre-formed polymer, polyE-323. The EOF direction in the microchannel was reversed by both TMSVE and polyE-323 coatings. The cation-selective preconcentration was investigated using charged fluorescent dyes and tetramethylrhodamine isothiocyanate (TRITC)-tagged peptides/proteins. The preconcentration in the three different systems was compared with respect to efficiency, dependence on buffer concentration and pH, tolerable flow rate, and sample adsorption. Both TMSVE- and polyE-323-coated nanochannels showed robust preconcentration at high flow rates, whereas the PDADMAC membrane maintained anion- permselectivity at higher buffer concentrations. The TMSVE-coated nanochannels showed a more stable preconcentration process, whereas the polyE-323-coated nanochannels showed a lower peptide sample adsorption and robust efficiency under a wide range of buffer pHs. The system described here can potentially be used for the preconcentration of cationic peptides/proteins on microfluidic devices for subsequent analyses.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHUN, Hong gu photo

CHUN, Hong gu
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE