Set-up uncertainty during breast radiotherapy Image-guided radiotherapy for patients with initial extensive variation
- Authors
- Yang, D. S.; Yoon, W. S.; Chung, S. Y.; Lee, J. A.; Lee, S.; Park, Y. J.; Kim, C. Y.; Son, G. S.
- Issue Date
- Apr-2013
- Publisher
- SPRINGER HEIDELBERG
- Keywords
- Breast cancer; Set-up error; Risk factor; Electronic portal image; Image-guided radiotherapy
- Citation
- STRAHLENTHERAPIE UND ONKOLOGIE, v.189, no.4, pp.315 - 320
- Indexed
- SCIE
SCOPUS
- Journal Title
- STRAHLENTHERAPIE UND ONKOLOGIE
- Volume
- 189
- Number
- 4
- Start Page
- 315
- End Page
- 320
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/103620
- DOI
- 10.1007/s00066-012-0271-4
- ISSN
- 0179-7158
- Abstract
- The aim of this work was to establish a customized strategy for image-guided radiotherapy during whole breast irradiation. Risk factors associated with extensive errors were assessed. A series of 176 consecutive breasts in 174 patients were retrospectively assessed. Electronic portal images from 914 medial and 807 lateral directions were reviewed. On the basis of the chest wall, the deviations between the simulation and each treatment were measured. The systematic (I ) pound and random error (sigma) of population, and the planning target volume (PTV) margin (2 I pound + 0.7 sigma) were calculated for each direction. Extensive set-up errors were defined as the fraction over the PTV margins in any direction. For extensive set-up errors, chi(2) tests and logistic regression analyses were conducted. The medial and lateral PTV margins for the right-left, superior-inferior, and anterior-posterior axes and the rotation of collimator were 2.6 and 2.4 mm, 4.6 and 4.6 mm, and 3.1 and 3.3 mm and 2.8 and 2.9 A degrees and cut-off values for extensive errors were 3, 5, and 4 mm and 3 A degrees, respectively. In chi(2) tests, tumor in upper outer quadrant (p = 0.012) and chest wall thickness a parts per thousand yenaEuro parts per thousand 2.0 cm (p = 0.003) for medial portals and age group (p = 0.036) for lateral portals were associated with extensive errors. In multivariate tests, the extensive error on the initial fraction had a high probability of extensive set-up errors in both medial (OR = 4.26, p < 0.001) and lateral portals (OR = 3.07, p < 0.001). In terms of the set-up uncertainty during breast irradiation, patients with extensive error in the initial treatment should be closely observed with serial image-guided radiotherapy.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Medical Science > 1. Journal Articles
- Graduate School > Department of Biomedical Sciences > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.