Potentiometric Multichannel Cytometer Microchip for High-throughput Microdispersion Analysis

Authors
Kim, JunhoiKim, Eun-GeunBae, SangwookKwon, SunghoonChun, Honggu
Issue Date
1-1월-2013
Publisher
AMER CHEMICAL SOC
Citation
ANALYTICAL CHEMISTRY, v.85, no.1, pp.362 - 368
Indexed
SCIE
SCOPUS
Journal Title
ANALYTICAL CHEMISTRY
Volume
85
Number
1
Start Page
362
End Page
368
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/104233
DOI
10.1021/ac302905x
ISSN
0003-2700
Abstract
The parallelization of microfluidic cytometry is expected to lead to considerably enhanced throughput enabling point-of-care diagnosis. In this article, the development of a microfluidic potentiometric multichannel cytometer is presented. Parallelized microfluidic channels sharing a fluid path inevitably suffer from interchannel signal crosstalk that results from electrical coupling within the microfluidic channel network. By employing three planar electrodes within a single detection channel, we electrically decoupled each channel unit, thereby enabling parallel analysis by using a single cytometer microchip with multiple microfluidic channels. The triple-electrode configuration is validated by analyzing the size and concentration of polystyrene microbeads (diameters: 1.99, 2.58, 3, and 3.68 mu m; concentration range: similar to 2 x 10(5) mL(-1) to similar to 1 x 10(7) mL(-1)) and bacterial rnicrodispersion samples (Bacillus subtilis, concentration range: similar to 4 x 10(5) CFU mL(-1) to similar to 3 x 10(6) CFU mL(-1)). Crosstalk-free parallelized analysis is then demonstrated using a 16-channel potentiometric cytometer (maximum cross-correlation coefficients vertical bar r vertical bar: < 0.13 in all channel combinations). A detection throughput of similar to 48 000 s(-1) was achieved; the throughout can be easily increased with the degree of parallelism of a single microchip without additional technical complexities. Therefore, this methodology should enable high-throughput and low-cost cytometry.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHUN, Hong gu photo

CHUN, Hong gu
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE