Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

High-purity CdMnTe radiation detectors: A high-resolution spectroscopic evaluation

Authors
Rafiei, R.Reinhard, M.I.Kim, K.Prokopovich, D.A.Boardman, D.Sarbutt, A.Watt, G.C.Bolotnikov, A.E.Bignell, L.J.James, R.B.
Issue Date
2013
Keywords
Carrier lifetime; CdMnTe; Charge collection efficiency; CMT; Compound semiconductor radiation detector; Crystal growth; Drift velocity; IBIC; Manganese purity; Mobility; Mobility-lifetime
Citation
IEEE Transactions on Nuclear Science, v.60, no.2, pp.1450 - 1456
Indexed
SCIE
SCOPUS
Journal Title
IEEE Transactions on Nuclear Science
Volume
60
Number
2
Start Page
1450
End Page
1456
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/105995
DOI
10.1109/TNS.2013.2243167
ISSN
0018-9499
Abstract
The charge transport properties of a high-purity CdMnTe (CMT) crystal have been measured at room temperature down to a micron-scale resolution. The CMT crystal, doped with indium, was grown by the vertical Bridgman technique. To reduce the residual impurities in the Mn source material, the growth process incorporated a five-times purification process of MnTe by a zone-refining method with molten Te solvent. The resulting 2.6 mm thick crystal exhibited an electron mobility-lifetime product of μnτn=2. 9× 10-3 cm2 V-1. The velocity of electron drift was calculated from the rise time distribution of the preamplifier's output pulses at each measured bias. The electron mobility was extracted from the electric field dependence of the drift velocity and at room temperature it has a value of μn=(950±90)cm2/Vs. High-resolution maps of the charge collection efficiency have been measured using a scanning microbeam of 5.5 MeV 4He2+ ions focused to a beam diameter < 1μm and display large-area spatial uniformity. The evolution of charge collection uniformity across the detector has been highlighted by acquiring measurements at applied biases ranging between 50 V and 1100 V. Charge transport inhomogeneity has been associated with the presence of bulk defects. It has been demonstrated that minimizing the content of impurities in the MnTe source material is highly effective in achieving major improvements in the CMT detector's performance as compared to previous data. © 1963-2012 IEEE.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE