Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Is it Feasible to Use the Commercially Available Autoquantitation Software for the Evaluation of Myocardial Viability on Small-Animal Cardiac F-18 FDG PET Scan?

Authors
Pahk, K.Oh, S.Y.Jeong, E.Lee, S.H.Woo, S.K.Yu, J.W.Choe, J.G.Cheon, G.J.
Issue Date
2013
Keywords
Autoquantitation; FDG PET; Myocardial infarct model; Myocardial viability
Citation
Nuclear Medicine and Molecular Imaging, v.47, no.2, pp.104 - 114
Indexed
SCOPUS
KCI
Journal Title
Nuclear Medicine and Molecular Imaging
Volume
47
Number
2
Start Page
104
End Page
114
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/106026
DOI
10.1007/s13139-013-0206-8
ISSN
1869-3474
Abstract
Purpose: To evaluate the reliability of quantitation of myocardial viability on cardiac F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) scans with three different methods of visual scoring system, autoquantitation using commercially available autoquantitation software, and infarct-size measurement using histogram-based maximum pixel threshold identification on polar-map in rat hearts. Methods: A myocardial infarct (MI) model was made by left anterior descending artery (LAD) ligation in rat hearts. Eighteen MI rats underwent cardiac FDG-PET-computed tomography (CT) twice within a 4-week interval. Myocardium was partitioned into 20 segments for the comparison, and then we quantitated non-viable myocardium on cardiac FDG PET-CT with three different methods: method A-infarct-size measurement using histogram-based maximum pixel threshold identification on polar-map; method B-summed MI score (SMS) by a four-point visual scoring system; method C-metabolic non-viable values by commercially available autoquantitation software. Changes of non-viable myocardium on serial PET-CT scans with three different methods were calculated by the change of each parameter. Correlation and reproducibility were evaluated between the different methods. Results: Infarct-size measurement, visual SMS, and non-viable values by autoquantitation software presented proportional relationship to each other. All the parameters of methods A, B, and C showed relatively good correlation between each other. Among them, infarct-size measurement (method A) and autoquantitation software (method C) showed the best correlation (r = 0.87, p < 0.001). When we evaluated the changes of non-viable myocardium on the serial FDG-PET-CT- however, autoquantitation program showed less correlation with the other methods. Visual assessment (method B) and those of infarct size (method A) showed the best correlation (r = 0.54, p = 0.02) for the assessment of interval changes. Conclusions: Commercially available quantitation software could be applied to measure the myocardial viability on small animal cardiac FDG-PET-CT scan. This kind of quantitation showed good correlation with infarct size measurement by histogram-based maximum pixel threshold identification. However, this method showed the weak correlation when applied in the measuring the changes of non-viable myocardium on the serial scans, which means that the caution will be needed to evaluate the changes on the serial monitoring. © 2013 Korean Society of Nuclear Medicine.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sung Ho photo

Lee, Sung Ho
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE