Non-contact measurement of current distribution in parallel conductors by using Hall sensors
- Authors
- Park, Myungjin; Byun, Sangbeom; Kim, Wooseok; Lee, Jikwang; Choi, Kyeongdal; Lee, Haigun
- Issue Date
- 6월-2008
- Publisher
- IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
- Keywords
- current distribution; Hall sensor; HTS
- Citation
- IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, v.18, no.2, pp.1135 - 1138
- Indexed
- SCIE
SCOPUS
- Journal Title
- IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
- Volume
- 18
- Number
- 2
- Start Page
- 1135
- End Page
- 1138
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/123429
- DOI
- 10.1109/TASC.2008.922512
- ISSN
- 1051-8223
- Abstract
- A parallel HTS conductor to flow large current is essential for applications of HTS power device. Non-uniform current distribution in the parallel conductor is caused mainly due to the difference of inductance. There are a contact method which measures current directly and a non-contact method which measure indirectly. But current distribution of each conductor in parallel conductors can not be measured with conventional method. In this paper, we researched a measurement method to identify current distribution of the parallel conductor indirectly with Hall sensors and compared with the analysis results by 2-D FEM.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > Department of Materials Science and Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.